Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test E] 36 Month Test <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10182155 5/ 14/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> System Transport <br /> Business Site Address City ZIP Code <br /> 707 East Roth Road French Camp 95231 <br /> IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Benjamin Duncan ( 707 ) 621 -0378 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Tank Tester License #90- 1120 5246802 - UT 3/21 /2021 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A T- 1 - Diesel B C D <br /> Tank Containment <br /> Tightness Test Result p Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result p Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result EI Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail p NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> j Communication Test Result ❑ Pass ❑ Fail p NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> rVent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail p NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result O Pass ElFail ElNA ElPass ❑ Fail ❑ NA ❑ Pass ElFail ❑ NA E] Pass E] Fail E] NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail M NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> VENT / TRANSITION SUMP ID : a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 1 Master 2 Satellite 3 Satellite 4 <br /> Tightness Test Result p Pass ❑ Fail ❑ NA El Pass <br /> El ❑ NA O Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> All items marked "Fail" or "NA " must be explained in their respective "COMMENTS" section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, Title 23 , Division <br /> 3 , Chapter 16, Section 2637 and all the information contained herein is accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, NA = Not Applicable, UDC = Under- <br /> Dispenser Containment <br />