Laserfiche WebLink
oPnUNCG SAN JDAQUIN Environmental Health Department <br /> COUNTY Wayne Fox , REHS , Interim Director <br /> PROGRAM COORDINATORS <br /> � iFoa?� Greatness grows here . <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Munviappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> July 6 , 2020 <br /> GUADALUPE SANCHEZ <br /> DIAMOND PETROLEUM SERVICES INC <br /> 3619 KING CT <br /> ANTIOCH , CA 94509 <br /> SR0082289 <br /> RE : ARCO AM PM #82602* <br /> 2430 JOE POMBO PKWY <br /> TRACY , CA 95376 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of <br /> the application for a permit to install (6) dispensers and to replace the Incon console with a Veeder <br /> Root TLS - 350 Plus console on the underground storage tank ( UST) system at the above noted <br /> address . The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District <br /> for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustaslgov . orq to arrange the following appointments ( a <br /> 48- hour notice is required for inspection appointments) . <br /> • Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs) . <br /> • Visual inspection of the piping within the dispensers . <br /> • Sensor functionality : Functionality of the monitoring system must be verified to ensure <br /> that monitoring has been restored to meet the requirements of Title 23 California Code <br /> of Regulations and the Health & Safety Code . A copy of the alarm history shall be <br /> printed prior to performing the " cold start" of the monitoring system and made <br /> available at the time of EHD inspection . <br /> 4 . If concrete will be broken near the tank , a secondary containment test must be performed <br /> on the tank once concrete is poured in accordance with the manufacturer's guidelines . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual <br /> by the State Water Board , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468- 3420 1 F 209 464-0138 1 www. sjgov . org/ehd <br />