My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2020 4:24:16 PM
Creation date
7/15/2020 9:26:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEURP1200 -12 <br /> ATGs are programmed to monitor the product level in warnings or alarms , In the event of any <br /> storage tanks and can be programmed to perform com- such warnings or alarms, notify the appro- <br /> pliance tests that can include 0.2 gph static and dynamic priate person before continuing the test. <br /> ("continuous") leak tests, and 0. 1 gph ("precision") tests . <br /> Where possible print out the system setup <br /> 8 .2 .1 ATG Functionality Test, and any alarm histories from the console, <br /> Save the printout for facility records or <br /> 8 . 2 . 1. 1 General . The ATG must be pro" make an electronic copy. <br /> grammed using site-specific parameters <br /> for the UST system to ensure proper opera- 8 . 2 . 1. 5 Test Equipment . Test equip- <br /> tion. On dual float systems, the second ment shall include: <br /> float indicates the level of water in the tools for the removal of the ATG probe <br /> tank. <br /> and sensors ; <br /> 8 .2 .1 .2 Purpose . The purpose of this tape measure or gauge stick; <br /> test is to : <br /> • <br /> • determine whether the ATG shows the water-finding paste, <br /> correct product level on the console, 8. 2 . 1.6 Test Procedure. <br /> • determine whether the ATG shows the 1. Measure the product and water level <br /> correct water level on the console; in the tank and compare to the console <br /> • verify that the water alarm is operating readings to confirm ATG accuracy. If <br /> correctly and provides a warning at the the readings do not agree, contact the <br /> programmed set point. <br /> appropriate person, <br /> 2 . Remove the ATG probe cap and discon- <br /> WARNING: Water ingress Into tanks con- nect the cable from the ATG , <br /> taining ethanol-blended gasoline may not 3 . Remove the ATG probe from the tank . <br /> be detected using water floats designed Use care to ensure that the floats on the <br /> for non-ethanol-blended gasoline , stem do not catch on the bottom of the <br /> riser during removal. <br /> 8 . 2 . 1. 3 Description of Test. The pro- 4. Inspect the probe. The floats must move <br /> cedures in this test are for a probe, properly freely on the stem without binding. If <br /> installed per manufacturer 's instructions, any parts are damaged or missing, con~ <br /> equipped with floats having a range inside tact the appropriate person, <br /> the tank that extends from the bottom to 5. Reconnect the probe cable, <br /> the top of the tank. <br /> 6 . Set the fuel float in the middle of the <br /> The ATG probe is removed from the tank, probe and verify that it is showing the <br /> The product float and water float positions correct inch reading on the console. <br /> are compared with the console readout. 7 . Slowly move the fuel float up the probe <br /> 8 . 2 . 1.4 Preparation . Use this test pro- until the high product alarm is triggered <br /> cedure in conjunction with the monitor- on the console. If the system does not <br /> 0 1 <br /> ing system manufacturer's installation and alarm at the <br /> re-set level contact t the <br /> maintenance instructions . appropriate person. <br /> Refer to the tank manufacturer 's tank S. Measure the distance from the bot- <br />, chart for the capacity in gallons , the diam- tom of the probe to the fuel float when <br /> triggers eter and the volume of product that come- the float first togg the high gh product <br /> sponds to the product level. alarm. <br /> Verify that the console has no active or 9 . Clear the alarm conditions . , <br /> recurring history of leak detection-related <br /> ® pei . org <br />
The URL can be used to link to this page
Your browser does not support the video tag.