Laserfiche WebLink
SANOAQU I N Environmental Health Department <br /> COUNT -( IY <br /> C rea rrie3 S grows here, Time In: 10.30 am <br /> Time Out: 11:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: YOGI BEARS JELLYSTONE PARK Date: 08/14/2018 <br /> Address: 14900 W HWY 12 , LODI 95242-9514 <br /> Owner/Operator: STOCKTON DELTA RESORT, LLC Telephone: (616)406-5755 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual <br /> OBSERVATIONS:Chlorine was measured at 0.8 ppm,the pool operator must maintain a free chlorine level between 1.0 <br /> and 10.0 ppm. Corrected on site, chlorine is now 1.0 ppm. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:There are float valve assemblies and weirs missing, replace them by the next routine inspection. <br /> There was one duck cover that was stuck and I could not pry it off. Fix before next routine inspection. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #29 Recirculation System Operation <br /> OBSERVATIONS: <br /> CALCODE DESCRIPTION:Recirculation system shall be in operation whenever the pool is available for use and additional times as <br /> needed to maintain clear pool water. (CCR 65525) <br /> #30 Pool Equipment and Plumbing Maintained <br /> OBSERVATIONS:There is one skimmer that is lacking circulation, and the water has become stagnant. Ensure that <br /> plumbing is well maintained. <br /> CALCODE DESCRIPTION:All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br /> specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br /> 3123B) <br /> FA0000527 PR0536402 SCO01 08/14/2018 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />