FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2537
>
3500 - Local Oversight Program
>
PR0545857
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 10:51:36 PM
Creation date
7/15/2020 2:37:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0545857
PE
3528
FACILITY_ID
FA0005147
FACILITY_NAME
E-Z FOOD
STREET_NUMBER
2537
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
11914035
CURRENT_STATUS
02
SITE_LOCATION
2537 WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEoENVIRO SERVICES, INC. <br /> ATTACHMENT A <br /> Soil Vapor Survey Sampling Procedures <br /> Former EZ-Serve 100966, 2531 Waterloo Road <br /> Stockton, California <br /> Soil Vapor Survey Scope <br /> GESI will conduct a soil vapor survey to evaluate vapor intrusion risk to indoor air in the building onsite. <br /> The survey will include the collection of shallow soil vapor samples in the vicinity of the building onsite. <br /> The data collected will be used to evaluate potential human health risks associated with exposure to <br /> hydrocarbons in soil vapor at the site. <br /> GEST will complete two temporary soil gas probes for collection of vapor samples. Vapor sampling will <br /> be completed in accordance with the Department of Toxic Substances Control (DTSC's) and Los <br /> Angeles Regional Water Quality Control Board's (LARWQCB's) "Advisory — Active Soil Gas <br /> Investigation" (DTSC and LARWQCB, 2003) and DTSC's "Interim Final Guidance for the Evaluation and <br /> Mitigation of Subsurface Vapor Intrusion of Indoor Air" (DTSC, 2005). <br /> Installation of Vapor Probes <br /> Each vapor probe will be completed by advancing 1.25-inch diameter steel rods equipped with a <br /> hardened steel tip. The probe will be advanced to 5-feet using hydraulic push methods. Once driven to <br /> total depth, the tip will be retracted to expose the vapor sampling port. A %-inch diameter nylon tube will <br /> extend from the sampling port to above ground surface. The probe will be sealed at the surface with <br /> granular hydrated bentonite for a minimum of 20 minutes prior to sampling. <br /> Soil Gas Sampling <br /> Following probe installation, a leak test and a purge volume test will be conducted according to DTSC <br /> protocol. Purging and sampling will be times so that the flow rate does not exceed 200 ml/minute. The <br /> probe tip and sampling tubing will be purged of 3 to 5 casing volumes, or a pre-determined volume based <br /> upon the purge volume test. Laboratory prepared Summa canisters containing a check valve to ensure <br /> the flow rate is less than 200 ml/min will be used to withdraw a soil gas sample from each probe location. <br /> Soil Gas Sample Analysis <br /> The soil gas samples will be collected in Summa canisters and submitted to a State-certified testing <br /> facility according to EPA Method TO-3. The samples will be analyzed within 72 hours of collection for <br /> total petroleum hydrocarbons as gasoline(TPHg), benzene, toluene, ethylbenzene, and xylenes (BTEX), <br /> and fuel oxygenates. <br /> 5529 Kailas Street - Ventura - CA - 93003 - T 805 . 642 . 1668 - F 805 . 642 . 9331 <br /> PO Box 7330 - Ventura - CA - 93006- 7330 <br />