Laserfiche WebLink
EZ-SERVE <br /> QUARTERLY GROUNDWATER MONITORING PROGRAM <br /> SAMPLING AND ANALYSIS PLAN <br /> The following sections describe the procedures and protocols to be followed during the <br /> quarterly groundwater monitoring events at all EZ-Serve sites <br /> Depth-to-Water Measurements <br /> Prior to sampling the groundwater monitoring wells, the wells will be opened to the <br /> atmosphere for approximately one-quarter of one hour, to allow the static water level to adjust <br /> to the open barometric pressure The depth-to-groundwater will then be measured, using an <br /> oil-water interface probe, and a check for free-product on top of the water column will be <br /> made The interface probe will be lowered slowly until free product or water is encountered. <br /> At this point, the mark on the interface probe wire will be read to the nearest 0.01 feet at the <br /> permanent reference point on the top of the well casing If free product is encountered the <br /> probe will be lowered until water is encountered The difference between the two depths will <br /> correspond to the thickness of the free product The total depth of the well will then be <br /> measured using the same probe. A bailer will then be lowered into the water to approximately <br /> one-half the bailer length The bailer will be checked for the presence of a product sheen <br /> In the event that a dedicated bailer or purge tubing exists in the well the dedicated equipment <br /> will be removed prior to checking the depth-to-water, and temporarily stored in a clean, plastic <br /> garbage bag. <br /> The depth-to-water and bottom of well measurements, and the presence or absence of free <br /> product, will be recorded on the field sampling form In addition, comments regarding the <br /> condition of the well and/or containment box will also be noted on the field sampling sheet at <br /> this time Wells observed to contain a product sheen or free product on top of the water <br /> column will not be purged or sampled. <br /> Groundwater Monitoring Well Purging <br /> The depth-to-water and bottom of well measurements will be used to calculate the <br /> volume of water contained in one well volume The following values will be used to calculate <br /> the volume of water contained in the well casing and filter pack surrounding the well. <br /> Well Diame a Gallons/linear foot <br /> 2-inch 0 16 <br /> 4-inch 065 <br /> 8-inch filter pack 078 <br /> 10-inch filter pack 121 <br /> The minimum purge volume will be three times the calculated well volume. Once the <br /> minimum purge volume has been calculated purging will begin. Purging will be conducted <br />