Laserfiche WebLink
I 1 <br /> ' APPENDIX G <br /> ' GROUNDWATER MONITORING WELL CONSTRUCTION PROCEDURES <br /> tBOREHOLE DESIGN <br /> Casing Diameter: The minimum diameter of well casings will be 4 <br /> inches (nominal) . <br /> Borehole Diameter: The diameter of the borehole will be a <br /> minimum of 10 inches and a maximum of 12 inches greater than the <br /> ' diameter of the well casing. The minimum annular space will be 3 <br /> inches as measured from the outside diameter of the casing to the <br /> drill hole wall . <br /> ' Shallow Unconfined Zone Wells - When unconfined groundwater is <br /> encountered the borehole will be advanced through the aquifer to <br /> an underlying clay layer or aquitard The screened interval will <br /> ' begin a minimum of 5 feet above the saturated zone or above the <br /> anticipated seasonal high level of groundwater. The screen will <br /> extend the full thickness of the aquifer or no more than 15 feet <br /> into the sa'Zurated zone, whichever is reached first . The well <br /> ' screen will not extend into the aquitard, nor will the screened <br /> interval exceed 20 feet in length. <br /> Deep (Confined Zone) Wells : Any monitoring well to be screened <br /> below the upper aquifer will be installed as a double-cased well . <br /> A steel conductor casing will be placed through the upper water- <br /> bearing zone to prevent aquifer cross-contamination <br /> The conductor casing will be installed in the following manner: a <br /> large diameter borehole (typically 18 inches) will be drilled <br /> ' until it is determined that the first competent aquitard has been <br /> reached A low carbon steel conductor casing will be placed in <br /> the borehole to the depth drilled. Centralizers will be used to <br /> ' center the casing in the borehole . The annular space between the <br /> conductor casing and the formation will be cement-grouted prom <br /> bottom to top by tremae pipe method . The grout will be allowed <br /> to set for a minimum of 72 hours <br /> Drilling will continue inside the conductor casing, with a drill <br /> bit of smaller diameter than the conductor casing . If additional <br /> known aquifers are to be fully penetrated, the procedure will be <br /> repeated with successively smaller diameter conductor casings. <br /> The bottom of the well screen in a confined aquifer will be <br /> determined by presence or lack of a clay layer or aquitard as <br /> described above. The screened interval in a confined zone shall <br /> extend across the entire saturated zone of the aquifer or up to a <br /> length of 20 feet , which ever is less The screened zone and <br /> filter pack will not cross-connect to another aquifer . <br />