My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STRATFORD
>
1223
>
3600 - Recreational Health Program
>
PR0360141
>
COMPLIANCE INFO_COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 10:12:41 PM
Creation date
7/15/2020 2:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO
RECORD_ID
PR0360141
PE
3611
FACILITY_ID
FA0001276
FACILITY_NAME
STRATFORD APARTMENTS
STREET_NUMBER
1223
STREET_NAME
STRATFORD
STREET_TYPE
CIR
City
STOCKTON
Zip
95207
APN
10814003
CURRENT_STATUS
01
SITE_LOCATION
1223 STRATFORD CIR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> Grectne55 grows here. Time In: 1.00 pm <br /> Time Out: 2:00 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: STRATFORD APARTMENTS Date: 08/10/2018 <br /> Address: 1223 STRATFORD CIR, STOCKTON 95207 <br /> Owner/Operator: STONE BROS AND ASSOCIATES Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #4 Safety Equipment <br /> OBSERVATIONS:The life ring was tangle upon arrival.The life ring must be deployable at all times. Untangle and organize <br /> the life ring. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained, readily visible, and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #7 Pool Deck <br /> OBSERVATIONS:Vegetation is growing into the pool area, Operator must maintain a clean deck. Remove vegetation on <br /> next routine service. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31148)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool light is out,the operator needs to provide a light that lights the entire pool during dark hours. <br /> Replace the light within one month. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:The weirs are missing. Replace the weirs before the next routine inspection. <br /> There is one float valve assembly missing, replace before the next routine inspection. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31366) <br /> FA0001276 PR0360141 SCO01 08/10/2018 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.