Laserfiche WebLink
(A) designed or operated to contain 100 percent of the capacity of the largest tank <br /> within its boundary; <br /> (B) designed or operated to prevent run-on and infiltration of precipitation into the <br /> secondary containment system unless the collection system has sufficient excess <br /> capacity, in addition to that required in subsection (e)(1)(A) of this section, to contain <br /> run-on and infiltration. Such additional capacity shall be sufficient to contain run-on and <br /> infiltration of precipitation from a 25-year, 24-hour rainfall event, <br /> (C) free of cracks or gaps; and <br /> (D) designed and installed to completely surround the tank and to cover all surrounding <br /> earth likely to come into contact with the waste if released from the tank(s) (i.e., capable <br /> of preventing lateral as well as vertical migration of the waste). <br /> (2) Vault systems shall be: <br /> (A) designed or operated to contain 100 percent of the capacity of the largest tank <br /> within its boundary; <br /> (B) designed or operated to prevent run-on and infiltration of precipitation into the <br /> secondary containment system unless the collection system has sufficient excess <br /> capacity, in addition to that required in subsection (e)(2)(A) of this section, to contain <br /> run-on and infiltration. Such additional capacity shall be sufficient to contain run-on and <br /> infiltration of precipitation from a 25-year, 24-hour rainfall event; <br /> (C) constructed with chemical-resistant water stops in place at all joints (if any); <br /> (D) provided with an impermeable interior coating or lining that is compatible with the <br /> waste being transferred, stored or treated and that will prevent migration of waste into <br /> the concrete; <br /> (E) provided with a means to protect against the formation of and ignition of vapors <br /> within the vault, if the waste being transferred, stored ortreated. <br /> 1. meets the definition of ignitable waste under section 66262.21 of this division, or <br /> 2. meets the definition of reactive waste under section 66261.23 of this division and <br /> may form an ignitable or explosive vapor,and <br /> (F) provided with an exterior moisture barrier or be otherwise designed or operated to <br /> prevent migration of moisture into the vault if the vault is subject to hydraulic pressure. <br /> (3) Double-walled tanks shall be: <br /> (A) designed as an integral structure (i.e., an inner tank within an outer shell) so that <br /> any release from the inner tank is contained by the outer shell, <br /> Hazardous Waste Tank Assessment Report Martin Consulting <br /> Oil Stop,301 W.Kettleman Lane Page 15 of 29 Group,Inc.—Structural Design <br />