n manage hazardous wastes generated onsite, and which meet the criteria specified in <br /> subsection 6)(2) of this section: <br /> (A) prior to the tank system or component being placed in service for new tank systems <br /> or components; or <br /> (B) by January 24, 1998 for existing tank systems. <br /> (2) The provisions of subsection Q)(1) of this section apply only to: <br /> (A) on ground or aboveground tank systems containing only non-RCRA hazardous <br /> wastes generated onsite, and tank systems authorized under Permit-by-Rule pursuant <br /> to Chapter 45 of this division, Conditional Authorization pursuant to HSC 25200.3, and <br /> Conditional Exemption pursuant to HSC 25201.5, and <br /> (B) on ground or aboveground tank systems containing RCRA hazardous wastes <br /> generated onsite, if: <br /> 1. the owner or operator is a conditionally exempt small quantity generator as defined in <br /> 40 CFR section 261.5, or a small quantity generator of more than 100 kg but less than <br /> 1000 kg per month as defined in 40 CFR section 265.201, or <br /> 2. the owner or operator is not subject to regulation in 40 CFR part 265 pursuant to an <br /> exemption in 40 CFR section 265.1, but the owner or operator is subject to the <br /> standards of this article. <br /> (k) A generator or owner or operator authorized pursuant to Permit-by-Rule pursuant to <br /> Chapter 45 of this division, Conditional Authorization pursuant to HSC 25200.3, or <br /> Conditional Exemption pursuant to HSC 25201.5, operating a non-RCRA underground <br /> tank system or an underground tank system otherwise exempt from permitting <br /> requirements pursuant to the federal act, shall comply with the applicable standards of <br /> Title 23 of the California Code of Regulations relating to underground tank systems. <br /> (1)) Secondary containment for on ground or aboveground generator and onsite tier <br /> (Permit-by Rule, Conditional Authorization, and Conditional Exemption), non-RCRA <br /> tank systems or tank systems otherwise exempt from permitting requirements pursuant <br /> to the federal act, shall consist of any of the devices listed in subsection (d) and satisfy <br /> the requirements of(e) of this section or consist of any device or combination of devices <br /> as approved in writing by the COPA, or the Department if there is no CUPA or the <br /> CUPA requests that the Department make a determination, which would satisfy the <br /> following minimum requirements: <br /> (1) designed, installed, and operated to prevent any migration of wastes or accumulated <br /> liquid out of the system to the soil, ground water, surface water, or air at any time during <br /> the use of the tank system,and <br /> (2) capable of detecting and collecting releases and accumulated liquids until the <br /> collected material is removed. <br /> Hazardous Waste Tank Assessment Report Martin Consulting <br /> Oil Stop,301 W. Kettleman Lane Page 20 of 29 Group,Inc.—Structural Design <br />