My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 8:34:53 AM
Creation date
7/15/2020 4:46:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ffffl'C ® TS- STS SumpSystemTest Pg , <br /> Franklin Fueling Systems <br /> Quick eGuide <br /> TS-STS Overview 1 TS-STS Installation <br /> The TS-STS system includes a TS-STS console within a convenient I <br /> portable case, leak testing probes with 50 feet of cable, and probe 1.) Required Materials: <br /> hanging hardware (slip rings and chain). a.) Tape to secure the probe cable b.) Safety cones & signs <br /> After all fittings within the sump are sealed, the sump is filled with a c.) Grounded, 3-pronged extension cord <br /> water-based test solution that covers all sump penetration holes. The <br /> probe is installed so the float is floating on the surface of the test solution. d.) Flat pieces of metal to suspend leak testing probe over sumps <br /> The TS-STS console is quickly programmed with the site name and 2 ) Work safely— install Safety Cones and Signs at the site <br /> address, number of sumps, the 7-digit code-names for each sump, and <br /> the correct Time/Day/Date before leak testing. 3.) The probes are precision instruments— handle with care! <br /> Pressing the Test key at the console keypad starts sump leak tests for 4.) The STS probes are shipped with cables attached, do not remove <br /> all sumps. The test time is 15 minutes and tests for a level change the cable from the probe end... remove at the console case only. <br /> greater than 0.002 inches. If the level of a sump drops more than the 5.) Inspect probes for proper float movement before use, then install <br /> leak limit during the test, the Sump Leak Test Report will show a fail probes as shown in Section 1 <br /> result when the test is finished. Leak tests can also be programmed <br /> (scheduled) to start at desired times. 6.) Connect the yellow probe cables to the receptacles at the TS-STS <br /> When finished, leak test reports will automatically print out at the console case. Make sure to line up keyways before inserting cable and <br /> tightening the screw-on connector. <br /> printer. Extra copies of this report can be printed using the report key. A <br /> newly completed Sump Leak Test will overwrite the previous results 7.) Locate the TS-STS case outside of the Hazardous Area and tape <br /> stored in memory. Save sump leak test reports and provide copies as the cable down to prevent probe movement during the test and to <br /> evidence of compliance with regulations. reduce tripping hazards <br /> Recommendation: Use a computer and the Tech version of 8.) Setup/ Program the TS-STS console per Section 2 <br /> System Sentinel Tm to record site data,sump code-names, and test <br /> results. Test results can also be extracted from Comm Port 1 at 9•) Start sump leak test(s) on sumps that are ready <br /> N0the bottom of the TS-STS console (also see Section 4). 10.) Always clean, dry, and store probes in the probe carrying case after <br /> Reference Federal and State regulations for leak limit and test each use <br /> time requirements. Recommendations for locating the TS-STS <br /> console outside of the(Class 1,Division 1, Group D)Hazardous Areas 11.) Test each of the probes on a monthly basis to ensure its ability to <br /> during testing,are based on NFPA 30,NFPA 30A and NFPA 70(NEC). detect leaks. Install the probe in a test container and initiate a test. <br /> After 5 minutes, remove about 0.12 inches of water.When the test <br /> INCON P/N 000-3004 Rev.D Feb.2009 © www.fraklinfuelino.com completes, the test report should show a Failed result if the probe <br /> This document may change without prior notice. INCON® is a Registered Trademark of Franklin Fueling Systems <br /> is working properly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.