Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> -:a U ;� i `Y I AMENDED <br /> 6/17/2020 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#32190 4943 S HWY 99 , STOCKTON April 22, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a <br /> DO. <br /> OBSERVATION: The designated operator employee training for Kham Chanthavong expired on 6/6/2019 and <br /> training was not performed until 6/15/2020. <br /> -Employee training for Yazan Aldaman expired on 10/3/2019 and training was not performed until 2/4/2020. <br /> -Employee training for Mohammed Khan expired on 2/15/2020 and training has not been performed. <br /> -Employee training for Singh Gurrajan expired on 4/9/2020 and training has not been performed. <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees.The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies, leak detection, monitoring alarms, spills and overfills. At least <br /> one of the facility employees present during operating hours shall have current training. <br /> CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on <br /> site, and submit a copy of the training records to the EHD. <br /> This is a repeat violation, Class II. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> OBSERVATION:A current copy of the UST operating permit was not found on site. The most recent permit on site <br /> was dated 1/7/2019. <br /> REGULATION GUIDANCE:A copy of the UST operating permit and all attachments and conditions shall be <br /> retained at the facility. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the 2020 permit and retain it on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted on 4/22/2019. The testing was not witnessed in its entirety. <br /> Looked inside all sumps and UDCs. Verified proper sensor locations. Verified spill bucket 5 gallon capacity. <br /> Verified all test boots are open. Paperwork inspection is still needed. A checklist was left on site; a complete <br /> report will be provided at the time of paperwork inspection. An inspection checklist was provided to the facility <br /> operator on the day of inspection. A complete report was finished on 6/17/2020 and replaces the initial <br /> checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0007458 PR0506488 SCO01 04/22/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />