My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:36:21 PM
Creation date
7/16/2020 1:21:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516736
PE
2361 - UST FACILITY
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
2802 COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> SAN OAQ N Environmental Health Department <br /> COUNTY Wayne Fox , RENS , Interim Director <br /> PROGRAM COORDINATORS PRO <br /> Greatness grows here . Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> July 17 , 2020 <br /> Dan Rauscher <br /> Granite Petroleum <br /> 3726 E . Boone Ave . <br /> Spokane , WA 99202 <br /> Re : Safeway Fuel Center # 1769 SR0082221 <br /> 2802 Country Club Blvd . , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to : <br /> - replace fill sump manways , risers , and lids <br /> - replace STP sump manways and lids <br /> - replace annular manways <br /> - replace probe risers <br /> - replace turbines <br /> - replace the 91 fill sump penetration with a split repair boot <br /> - replace rigid steel and flex piping inside the STP sumps <br /> - replace spill buckets <br /> - install flappers ( not listed as primary overfill in CERS ) <br /> on the underground storage tank ( UST) system at the above noted address . The permit has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (cDsiaov . org or contact Stacy Rivera at (209 ) 468 - 3420 to <br /> arrange the following inspection appointments ( a 48 - hour notice is required for inspection <br /> appointments ) . <br /> a . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> b . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> c . Verification that ball float(s ) , if installed , do not interfere with the installed flapper valve . <br /> d . Primary piping soap test on product piping : One hour pneumatic pressure test at 110 % of <br /> operating pressure , or 40 psi , whichever is greater. <br /> e . Leak detector test : Leak detector must be tested to confirm that the device can detect a <br /> leak of 3 gallons per hour at 10 psi . <br /> f. 24 - hour hydrostatic test ( or equivalent) on the 91 fill sump . <br /> g . Since concrete will be broken near the tanks and piping , a secondary containment test must <br /> be performed on the affected components once concrete is poured in accordance with the <br /> manufacturer' s guidelines . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464 - 0138 1 www . sjgov . org/ehd <br />
The URL can be used to link to this page
Your browser does not support the video tag.