My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CO0050077
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
32003
>
2200 - Hazardous Waste Program
>
CO0050077
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 2:56:04 PM
Creation date
7/16/2020 3:28:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
RECORD_ID
CO0050077
PE
2200
STREET_NUMBER
32003
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95377
APN
25309010
ENTERED_DATE
7/9/2019 12:00:00 AM
SITE_LOCATION
32003 S TRACY BLVD
RECEIVED_DATE
7/8/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
ADMIN
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
591
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Case Narrative <br /> Client: Ghilotti Construction Company Inc Job ID: 720-93317-1 <br /> Project/Site: Hayward 680 Alamo <br /> Job ID: 720-93317-1 <br /> Laboratory: Eurofins TestAmerica, Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-93317-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 6/4/2019 10:04 AM;the samples arrived in good condition, properly preserved and,where required, on ice. <br /> The temperature of the cooler at receipt was 1.0°C. <br /> GC/MS VOA <br /> Method(s)8260B:The matrix spike/matrix spike duplicate(MS/MSD)recoveries and precision for preparation batch 720-266653 and <br /> analytical batch 720-266845 were outside control limits. Sample matrix interference and/or non-homogeneity are suspected because the <br /> associated laboratory control sample/laboratory sample control duplicate(LCS/LCSD)precision was within acceptance limits. <br /> Method(s)8260B: Due to the high concentration of Naphthalene,the matrix spike(MS)for preparation batch 720-266653 and analytical <br /> batch 720-266845 could not be evaluated for accuracy. The associated laboratory control sample(LCS)met acceptance criteria. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> GC Semi VOA <br /> Method(s)8081 A:The%RPD between the primary and confirmation column/detector exceeded 40%for trans-Chlordane for the following <br /> sample:#1-3EA(720-93317-1). The lower value(s)has been reported and qualified in accordance with the laboratory's SOP. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> Metals <br /> Method(s)6010B:The method blank for preparation batch 720-266989 and analytical batch 720-267098 contained Barium above the <br /> method detection limit. This target analyte concentration was less than the reporting limit(RL);therefore, re-extraction and/or re-analysis <br /> of samples was not performed. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> Organic Prep <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> Eurofins TestAmerica, Pleasanton <br /> Page 4 of 31 6/7/2019 <br />
The URL can be used to link to this page
Your browser does not support the video tag.