My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 4:16:59 PM
Creation date
7/21/2020 8:05:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Tracy Blvd Chevron 3775 N TRACY BLVD,TRACY February 16, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the monitoring system certification, spill <br /> containment, and leak detector testing on the June, July, and August 2018 designated operator monthly inspection <br /> reports. Designated operator marked 5/15/2017 instead of 2/21/2017.The designated operator failed to check and <br /> note the correct test date for the Secondary Containment testing on the January 2018 designated operator monthly <br /> inspection report. Designated operator marked 3/16/2016 instead of 3/3/2016. During the monthly inspection,the <br /> designated operator shall check that all required testing and maintenance for the UST system have been completed <br /> and document the dates they were done. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> The designated operator failed to document all the alarms from the attached alarm history on the January 2018 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: L13 Diesel Fill Fuel alarm on 1/8/2018 and two L14 Supreme Fill Fuel alarms on 1/9/2018. <br /> During the monthly inspection,the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 313 HSC 25290.1,25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> In dispenser 3/4, liquid observed in the under containment dispenser and weepage observed on product piping, <br /> indicating a leak in the primary piping. All primary containment for the UST system must be tight. Immediately have <br /> a properly licensed,trained, and certified contractor repair or replace the failed component under permit and <br /> inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 15, 2018. <br /> Documents reviewed by regulatot: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST <br /> Response Plan, UST Letter from Chief Financial Officer, the Owner Statement of Designated Operator <br /> Compliance and monthly reports (12 months), UST Monitoring Plans, Operating Permit, alarm history and setup, <br /> maintenance records, and employee training log. <br /> Documents received by facility: Return to compliance certification form and routine inspection report. <br /> Note: When it fails, the 87, 91, and diesel fill spill containments shall be replaced with a spill containment that <br /> has a minimum capacity of 5 gallons, is protected from galvanic corrosion, and has either a drain valve which <br /> allows drainage of the collected spill into the primary container or provide a means to keep the spill container <br /> FA0003715 PR0231418 SCO01 02/16/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.