RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Elite IV Contractors Page 1 of 2 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: Sump Manufacturer X Industry Standard Professional Engineer <br /> Caldwell Other(Specify) <br /> Test Method Used: Pressure Vacuum X Hydrostatic <br /> Caldwell Other(Spec) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> Sump 91 Sump Diesel Sump Sump <br /> Sump Diantelei: 30" 30" <br /> Sump Depth: 61" 61" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 38" 36" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 24" 25" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Clean Clean <br /> Portion of Sump Tested' Lower Lower <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X Yes No NA X Yes No NA Yes No NA Yes No NA <br /> product and water)? <br /> Turbine shutdown response time 5 Seconds 5 Seconds <br /> Is system programmed for fail-safe <br /> shutdown? X Yes No NA X Yes No NA Yes No NA Yes No NA <br /> Was fail-safe verified to be <br /> operational? X Yes No NA X Yes No NA Yes No NA Yes No NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 0 0 <br /> test: <br /> Test Start Time: 10:30 11:30 <br /> Initial Reading(R,): <br /> Test End Time: 11:30 12:30 <br /> Final Reading(RF): <br /> Test Duration: 1hr 1hr <br /> Change in Reading(RF-R,): 0 0 <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: X Pass ❑Fail X Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? X Yes No NA X Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and X Yes No NA X Yes No NA Yes No NA Yes No NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />