My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 3:13:41 PM
Creation date
7/21/2020 8:09:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Tracy Texaco 2375 N TRACY BLVD TRACY jlseptember 23 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> 1) Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br /> documents in CERS are dated 9/12/2018. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> 2)Current financial responsibility documents were not found on site. A copy of current financial responsibility <br /> documents are required to be maintained on site. Immediately obtain a copy of the facility's financial responsibility <br /> documents and maintain a copy on site. <br /> This is a minor violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 9/10/2018 <br /> and a test report was submitted on 3/14/2019, 5 months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a minor violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form"not submitted <br /> within 30 days. <br /> A new designated operator,Alex Jebbari, began conducting inspections on 7/17/2019 and notification was not <br /> provided to the EHD within 30 days of the change. The owner or operator shall submit a"Designated Underground <br /> Storage Tank Operator Identification Form"no later than 30 days after any change in the designated UST operator(s). <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov and upload <br /> the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> FA0006443 PR0231897 SCO01 09/23/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.