Laserfiche WebLink
D. Results of Testing/Servicing <br /> Software Version Installed : 333 .01 <br /> Complete the following checklist: <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected , functionally tested , and confirmed operational ? <br /> ❑ Yes ® No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station , is all communications equipment (e.g. , modem) operational? <br /> ® N/A <br /> ® Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br /> ❑ N/A fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) ® Sumpfrrench <br /> Sensors; ® Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le. , no mechanical overfill prevention valve is <br /> ® N/A installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity <br /> does the alarm trigger? % <br /> ❑ Yes ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes , or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts in Section E, below. <br /> El Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br /> ® Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below, describe how and when these deficiencies were or will be corrected . <br /> E. Comments: DIESEL ANNULAR SENSOR WRAPAROUND STRAP NOT ATTACHED TO SENSOR PORPERLY <br /> SENSOR MUST BE REWRAPPED AND RETESTED <br /> 1'0 A K 1 4 20 , <br /> t t a °t <br /> ~~ 4 <br /> i <br /> Monitoring System Certification Page 2 of 4 2/21 /07 <br /> i <br />