My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012661 CASE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
444
>
3500 - Local Oversight Program
>
PR0544618
>
ARCHIVED REPORTS_XR0012661 CASE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2020 8:42:24 AM
Creation date
7/21/2020 8:35:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012661 CASE 2
RECORD_ID
PR0544618
PE
3528
FACILITY_ID
FA0006456
FACILITY_NAME
SJ CO MOTOR POOL SHOP
STREET_NUMBER
444
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15505005
CURRENT_STATUS
02
SITE_LOCATION
444 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ail <br /> u-+ <br /> r <br /> Enseco <br /> Accuracy is measured by Percent Recovery as in, <br /> .�. .. % recovery = measured concentration x IN <br /> (actual concentration) <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in; <br /> RPD = % recovery test 1 - % recover test 2 x 100 <br /> (% recovery test 1 + % recovery test 2)/2 <br /> Control limits for accuracy (percent recovery) are based on the average, <br /> historical percent recovery +/-3 standard deviation units. Control limits <br /> for precision (relative percent difference) range from 0 (identical <br /> duplicate DCS results) to the average, historical relative percent <br /> difference + 3 standard deviation units. In cases where there is not <br /> enough historical data, EPA limits or advisory limits are set, with the <br /> approval of the Quality Assurance department. <br /> IV Analysis Results <br /> Test methods may include minor modifications of published EPA Methods such <br /> as reporting limits or parameter lists. Reporting limits are adjusted to <br /> reflect dilution of the sample, when appropriate. Solid and waste samples <br /> -, are reported on an "as received" basis; i.e., no correction is made for <br /> moisture content, unless the method requires or the client requests that <br /> such correction be made. <br /> Results are on the attached data sheets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.