My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0502003
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2020 9:27:14 AM
Creation date
7/21/2020 9:23:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0502003
PE
2381
FACILITY_ID
FA0005297
FACILITY_NAME
SYSTEM TRANSPORT INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19332008
CURRENT_STATUS
02
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RE <br /> ""D <br /> Appendix VI CEI" <br /> MONITORING SYSTEM CERTIFICATION JUN 018 <br /> For Use By All Jurisdictions Within the State of California <br /> 19 2 <br /> Authority Cited:Chapter 6.7,Health and Safety Code; Chapter 16,Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report mZ W,. WMENTAL <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provid, F"A 9 IaRTI+4ENT <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems with n dkys of fest'ate: <br /> A. General Information <br /> Facility Name: SYSTEM TRANSPORT Bldg.No.: <br /> Site Address: 707 E. ROTH ROAD city: FRENCH CAMP Zip: 95231 <br /> Facility Contact Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-300C Date of Testing/Servicing: 5/30/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: DSL 2 Tank Size: 12 K Tank ID: Tank Size: <br /> ® In-Tank Gauging Probe. Model: M A G 2 ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 4 0 9 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 2 0 8 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank Size: Tank ID: Tank Size: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: SATELITE I Dispenser ID: <br /> ® Dispenser Containment Sensor(s). Model: 2 0 8 ❑ Dispenser Containment Sensor(s). Model: <br /> ® ShearValve(s). ❑ ShearValve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: I / 2 Dispenser ID: <br /> ® Dispenser Containment Sensor(s). Model: 2 0 8 ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ❑ ShearValve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: SATELITE 2 Dispenser ID: <br /> ® Dispenser Containment Sensor(s). Model: 2 0 8 ❑ Dispenser Containment Sensor(s). Model: <br /> ® ShearValve(s). ❑ ShearValve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all thatapply): ®System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0112 <br /> Testing Company Address: 416 21d STREET GALT,CA 95632 Date of Testing/Servicing: 5/30/2018 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page