My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
345
>
2300 - Underground Storage Tank Program
>
PR0540987
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 1:30:05 PM
Creation date
7/21/2020 9:33:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0540987
PE
2351
FACILITY_ID
FA0023459
FACILITY_NAME
Pilot Travel Center Lathrop - 1017
STREET_NUMBER
345
STREET_NAME
ROTH
STREET_TYPE
Rd
City
FRENCH CAMP
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
345 Roth Rd
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Pilot Travel Center Lathrop- 1017 345 Roth Rd Lathrop jAugust 23 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br /> containment shall be provided for all single-walled UST components. Immediately provide approved secondary <br /> containment for the filters under permit and inspection by the EHD. <br /> This is a minor violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. The leak detector was replaced twice while on site with like-for-like models. A <br /> second VMI tester box was used for additional testing. None of the three leak detectors was able to pass testing. <br /> The leak detector was replaced and retested during the inspection. A"UST Retrofit Verification with Inspector Already <br /> Onsite"form has been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by September 23, 2018. <br /> NOTE: The brine in UDCs 3/4, 5/6, 7/8, 9/10, and 11/12 was observed to be too low to view in the site gauges <br /> located in each UDC or to verify brine communication. A small amount of brine was observed at the bottom of <br /> each brine reservoir and no sensors were in alarm at the time of inspection. All brine sensors were verified to be <br /> functional. Additional brine was put into UDCs 3/4, 5/6, 7/8, 9/10, and 11/12 during the inspection. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 23, 2018 Inspector: Inspector Phone: <br /> k4Printed Name and Title: STACY RIVERA, Senior REHS (209) 468-3440 <br /> - Doug Humphreys, General Manager <br /> FA0023459 PRO540987 SC001 08/23/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.