Laserfiche WebLink
UNDERGROUNDSTORAGETANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection ❑x 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181485 12/19/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> YRC#813 <br /> Business Site Address City ZIP Code <br /> 1535 E.Pescadero Avenue Tracy 95304 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Austin Sterling (800)339-9930 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 804904 8339953 3/25/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> OPW 104049 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INF :..;. 3 <br /> Inspection Method ❑Manufacturer Guidelines(Specify): <br /> Used: E <br /> E 2 8 2012 <br /> ❑x Industry Code or Engineering Standard(Specify): PEI-1200 <br /> ❑Engineered Method(Specify): ENVIRONMENTAL HEALTH <br /> Attach the inspection procedures and all documentation required to determine the results. t ®rr 0 <br /> TANK ID:(By tank number,stored product,etc.) Waste oil 4000 gal Waste oil 1000 gal Anti-freeze 6000 gal Gear oil 6000 gal <br /> What is the tank inside diameter?(Inches) 80.00" 48.00" 92.00" 92.00" <br /> Is the fill piping secondarily contained? Z Yes ❑No El Yes ❑No ❑Yes ❑No El Yes ❑No <br /> Is the vent piping secondarily contained? Z Yes ❑No 0 Yes ❑No ❑Yes ❑No El Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW OPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑Shuts Off Flow 0 Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow Z Restricts Flow EI Restricts Flow El Restricts Flow <br /> ❑AA/Alarm ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes 0 No Z Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 64" 60" 82.8" 82.8" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 80% 125% 90% 90% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑Yes ❑x Yes ❑x Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V) ❑No(Specify in V.) ❑ No(Specify in V.) ❑ No(Specify in V) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results Z Pass ❑Fail ❑ Pass �Fail ❑x Pass ❑Fail 7Y7❑x Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signatur;09— <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=Cafifomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Cound,AN=Audible and Usual <br /> UN-109 www.unidocs.org 111 -Rev.06/14/18 <br />