My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PR0535342
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
29425
>
4700 - Waste Tire Program
>
PR0535342
>
PR0535342
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2020 5:32:38 PM
Creation date
7/22/2020 8:36:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4700 - Waste Tire Program
RECORD_ID
PR0535342
PE
4740
FACILITY_ID
FA0020390
FACILITY_NAME
RENEWED RESOURCES CORP
STREET_NUMBER
29425
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25312026
CURRENT_STATUS
02
SITE_LOCATION
29425 S MACARTHUR RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10992
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sri SsatUa <br /> 5769 0 Short East . <br /> • Tacoma,WA 98424 <br /> Tel: 253 922 2310 <br /> Far.263 822 5047 <br /> wevw aWne eom <br /> DATA QUALIFIERS AND ABBREVIATIONS <br /> E31: This analyte was detected in the associated method blank.The analyte concentration was determined not <br /> to be significantly higher than the associated method blank (less than ten times the concentration reported <br /> in the blank). <br /> 132: This analyte was detected in the associated method blank.The analyte concentration in the sample was <br /> determined to be significantly higher than the method blank (greater than ten times the concentration <br /> reported in the blank). <br /> Ci: Second column confirmation was performed. The relative percent difference value (RPD) between the <br /> results on the two columns was evaluated and determined to be <40%. <br /> C2: Second column confirmation was performed. The RPD between the results on the two columns was <br /> evaluated and determined to be> 40%. The higher result was reported unless anomalies were noted. <br /> C3: Second analysis confirmation was performed. The relative percent differance value (RPD) between the <br /> results on the two columns was evaluated and determined to be < 30%. <br /> 04: Second analysis confirmation was performed. The RPD between the results on the two columns was <br /> evaluated and determined to be > 30%. The original analysis was reported unless anomalies were noted. <br /> M: GCIMS confirmation was performed. The result derived from the original analysis was reported. <br /> D: The reported result for this analyte was calculated based on a secondary dilution factor. <br /> E: The concentration of this analyte exceeded the instrument calibration range and should be considered an <br /> estimated quantity. <br /> J: The analyte was analyzed for and positively identified, but the ass <br /> aciated numerical value is an estimated <br /> quantity. <br /> MCL: Maximum Contaminant Level <br /> MDL: Method Detection Limit <br /> MRL: Method Reporting Limit <br /> N: See analytical narrative <br /> ND: Not Detected <br /> PQL: Practical Quantitation Limit <br /> X1: Contaminant does not appear to be"typical" product. Elution pattern suggests it may be <br /> X2: Contaminant does not appear to be "typical" product. <br /> X3: Identification and quantitation of the analyte or surrogate was complicated by matrix interference. <br /> X4: RPD for duplicates was outside advisory QC limits. The sample was re-analyzed with similar results. The <br /> sample matrix may be nonhomogeneous. <br /> X4a: RPD for duplicates outside advisory QC limits due to analyte concentration near the method practical <br /> quantitation limit/detection limit. <br /> X5: Matrix spike recovery was not determined due to the required dilution. <br /> X5: Recovery and/or RPD values for matrix spike(imatrix spike duplicate)outside advisory QC limits. Sample <br /> was re-analyzed with similar results. <br /> X7: Recovery and/or RPD values for matrix spike(Imatrix spike duplicate) outside advisory QC limits. Matrix <br /> interference may be indicated based on acceptable blank spike recovery and/or RPD. <br /> X7a: Recovery and/or RPD values for this spiked analyte outside advisory QC limits due to high concentration <br /> of the analyte in the original sample, <br /> X8: Surrogate recovery was not determined due to the required dilution. <br /> X9: -Surrogate recovery outside advisory QC limits due to matrix interference. <br /> QAM REV 16 112003 n <br /> N <br />
The URL can be used to link to this page
Your browser does not support the video tag.