Laserfiche WebLink
Table A-8a. Facility H - Coal and Petroleum Coke-Fired Power Plant <br /> Source Description <br /> Facility Name, Manitowoc Power Station <br /> Location: Manitowoc, WI <br /> Facility Type: Utility <br /> Source Type: Circulating fluidized bed boiler (220,000 lb steam/hr <br /> capacity). <br /> Test Dates: May 30-31, 1991, September 25-26, 1991, October 29-30, 1991 <br /> Other fuel(s): Coal, petroleum coke <br /> Air pollution control Pulse jet baghouse with air-to-cloth ratio of 3:1. <br /> device(s) used: <br /> Test Conditions: Test 1: 100% Coal <br /> Test 2: 100% Petroleum coke <br /> Test 3: 80% Petroleum coke, 20%TDF <br /> Test Methods: Unknown <br /> Fuel Unknown <br /> Handling/Feeding: <br /> Testing Company: Clean Air Engineering <br /> Environmental Wisconsin DNR <br /> Agency: <br /> Reference: CAE (1991) <br /> Source Test Data Evaluation <br /> Yes No Unknown <br /> Data Expressed in Emission Factor Form X <br /> Baseline Fuel Test Data Available X <br /> Accurate Fuel Feed Rates X <br /> Multiple Baseline Fuels X <br /> Test Witnessed by or Prepa red for X <br /> Governmental Agency <br /> A-22 <br />