Laserfiche WebLink
Kennedy/Jenks Consultants <br /> TABLE 4 <br /> MEASURES FOR LEVEL C DECONTAMINATION <br /> Station 1 Equipment Drop 1 Deposit equipment used onsite <br /> (tools, sampling devices and <br /> containers, monitoring instru- <br /> ments, radios, clipboards, etc ) on <br /> plastic drop cloths Segregation at <br /> the drop reduces the probability of <br /> cross contamination During hot <br /> weather operations, a cool down <br /> station may be set up within this <br /> area <br /> Station 2 Outer Garment, Boots, 2 Scrub outer boots, outer gloves <br /> and Gloves Wash and and splash suit with decors <br /> Rinse solution or detergent water Rinse <br /> off using copious amounts of <br /> water <br /> • Station 3 Outer Boot and Glove 3 Remove outer boots and gloves <br /> Removal Deposit in container with plastic <br /> liner <br /> Station 4 Canister or Mask Change 4 If worker leaves Exclusion Zone to <br /> change canister (or mask), this is <br /> the last step in the <br /> decontamination procedure <br /> Worker's canister is exchanged, <br /> new outer gloves and boot covers <br /> donned, points taped, and worker <br /> returns to duty <br /> Station 5 Boot, Gloves and Outer 5 Boots, chemical-resistant splash <br /> Garment Removal suit, inner gloves removed and <br /> deposited in separate containers <br /> lined with plastic <br /> Station 6 Face Piece Removal 6 Facepiece is removed Avoid <br /> touching face with fingers <br /> Facepiece is deposited on plastic <br /> sheet <br /> Station 7 Field Wash 7 Hands and face are thoroughly <br /> • washed Shower as soon as <br /> possible <br /> i <br /> 1 <br /> 4 <br />