Laserfiche WebLink
TABLE 1 <br /> SUMMARY OF VAPOR EXTRACTION TEST RESULTS <br /> for i <br /> Knowles/Roek Property <br /> 102 South Wilson Way <br /> ' Stockton, Cal-.fornia <br /> (Page 1 of 3) <br /> Vapor Extraction Test using Test Well VW-1 <br /> ' Applied Vacuum - 38 to 39 5 inches of water <br /> Flow Rate - 50 6 to 52 8 cfm <br /> Radius of Influence - 30 to 35 feet � <br /> ' Elapsed Time - 2 hours <br /> Observation Distance Maximum Percent of <br /> Well ID to Induced Applied <br /> Extraction Vacuum Vacuum <br /> Well (inches <br /> (feet) of Water) <br /> VW-2 0 1 0 2 5 <br /> VW-3 27 0 4 1 0 <br /> VW-4 35 0 8 2 0 <br /> VW-5 35 0 2 <1 0 <br /> VW-6 23 3 0 7 6 <br /> =mw--13 32 0 38 1 0 <br /> Vapor Extraction Test using Test Well VW--2 <br /> Applied Vacuum - 14 inches of water <br /> Flow Rate - 50 6 to 52 8 cfm <br /> Radius of Influence - 30 to 35 feet <br /> Elapsed Time - 2 hours <br /> Observation Distance Maximum Percent of <br /> Well ID to Induced Applied <br /> Extraction Vacuum Vacuum <br /> well (inches <br /> (feet) of Water) <br /> VW-1 0 1 0 7 1 <br /> VW-3 27 0 6 4 3 <br /> VW- 4 35 0 5 3 6 <br /> VW-5 35 0 22 1 6 <br /> E <br /> VW-6 23 2 0 14 3 <br /> MW-13 32 0 5 3 . 6 <br /> 1 <br />