My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012222
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
102
>
3500 - Local Oversight Program
>
PR0545890
>
ARCHIVED REPORTS_XR0012222
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 12:22:48 PM
Creation date
7/22/2020 11:45:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012222
RECORD_ID
PR0545890
PE
3526
FACILITY_ID
FA0025958
FACILITY_NAME
ROEK BROTHERS CONSTRUCTION
STREET_NUMBER
102
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15502065
CURRENT_STATUS
02
SITE_LOCATION
102 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lie <br /> LABORATORY NARRATIVE <br /> Modified TO-3 <br /> Ground Zero Analysis, Inc. <br /> I ' Workorder#0508424 <br /> ' Five 1 Liter Tedlar Bag samples were received on August 19, 2005. The laboratory performed analysis for <br /> volatile organic compounds in air via modified EPA Method TO-3 using gas chromatography with photo <br /> ionization and flame ionization detection. The TPH results are calculated using the response of Gasoline. A <br /> molecular weight of 100 is used to convert the TPH pprnvresult to ug/L. The method involves concentrating <br /> up to 200 mL of sample. The concentrated aliquot is then dry purged to remove water vapor prior to <br /> ' entering the chromatographic system. See the data sheets for the repotting limits for each compound. <br /> Requirement TO-3 ATL Modifications <br /> Daily Calibration Standard Prior to sample analysis Prior to sample analysis and after the analytical batch</= <br /> ' Frequency and every 4-6 hrs 20 samples. <br /> Initial Calibration Calculation 4-point calibration 5-point calibration using average Response Factor <br /> using a linear <br /> ' regression model <br /> Initial Calibration Frequency Weekly When daily calibration standard recovery is outside 75- <br /> 125%,or upon significant changes to procedure or <br /> instrumentation <br /> Moisture Control Nafion system Sorbent system <br /> • Minimum Detection Limit(MDL) Calculated using the 40 CFR Pt. 136 App. B <br /> ' equation DL=A+3.3S, <br /> where A is intercept of <br /> calibration line and S is <br /> the standard deviation <br /> of at least 3 reps of low <br /> level standard <br /> ' Preparation of Standards Levels achieved Levels achieved through loading various volumes of the <br /> through dilution of gas gas mixture <br /> mixture <br /> ' Receiving_Notes <br /> There were no receiving discrepancies. <br /> ' Analytical Notes <br /> There were no analytical discrepancies. <br /> Definition of Data Qualifying Flags <br /> ' Seven qualifiers may have been used on the data analysis sheets and indicate as follows: <br /> B - Compound present in laboratory blank greater than reporting limit <br /> J - Estimated value. <br /> ' E- Exceeds instrument calibration range. <br /> S - Saturated peak. <br /> Q - Exceeds quality control limits. <br /> ' U- Compound analyzed for but not detected above the detection limit <br /> Page 2 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.