My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:27:03 PM
Creation date
7/22/2020 1:15:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
®GETTLER-RYAN INC. RECEIVEDIR Job# 1820_ 1786 <br /> D. Results of Testing/Servicing JUL 13 2018 SWRCB,January 2006 <br /> Software version Installed: 329 . 0 1 ENVIRONMENTAL <br /> Complete the following checklist HEALTH DEPARTMENT <br /> ® es ❑ NO, Is the audible alarm operational? <br /> m Yes ❑ No. Is the visual alarm operational? <br /> ❑ Yes ❑ No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ❑ Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper o ration? <br /> Yes No' If alarms are relayed to a remote monitoring station,is all communication equipment(e.g.modem)operational? <br /> ❑ N/A <br /> 0 Yes ❑ No' For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system <br /> ❑ WA detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check all that apply) <br /> El Sump/Trench Sensor; 0 Dispenser Containment Sensor.Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? FA Yes, ❑ No. <br /> 0 Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> ❑ N/A valve is installed),is the overfill warning alar visible and audible at the tank fill points)and operating property?If so,at what percent <br /> of tank capacity does the alar trigged 95 <br /> ❑ Yes ❑ No Was any monitoring equipment replaced?If yes,identify speck sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) []product; []Water If <br /> yes,describe causes in Section E,below. <br /> ❑ Yes ❑ No' Was monitoring system set-up reviewed to insure proper settings?Attach set-up reports,if applicable. <br /> Yes ❑ No; I Is all monitoring equipment operational per manufacture's specifications? <br /> In section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Monitoring System Certification Page 2 of 4 12107 <br />