,2 <br /> UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection ® 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181579 10/12/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As.) <br /> Tracy USD - Service Center <br /> Business Site Address City ZIP Code <br /> 1975 W. Lowell Ave Trac 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Andrew Bagley 209 367-4800 Ext. <br /> ContractoriTank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 774802 8012449 12/24/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> OPW. Emco Wheaton <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used: ❑ Manufacturer Guidelines(Specify) <br /> ® Industry Code or Engineering Standard (Specify)PEI/RP1200-17 <br /> ❑ Engineered Method (Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages: <br /> Tank ID: (By tank number,stored product,etc.) 252101/Dsl/10k 252102/87/10k <br /> What is the tank inside diameter?(Inches) 95 95 <br /> Is the fill piping secondarily contained? ® Yes ❑ No ®Yes ❑ No ❑ Yes ❑No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ No ®Yes ❑ No ❑Yes ❑No ❑Yes ❑ No <br /> Emco Wheaton OPW <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment ®Shuts Off Flow ®Shuts Off Flow ❑ Shuts Off Flow ❑Shuts Off Flow <br /> response when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) <br /> ❑AN Alarm ❑AN Alarm ❑AN Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ® No ❑Yes ® No ❑Yes ❑ No ❑Yes ❑ No <br /> At what level in the tank is the overfill prevention 82 <br /> set to activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 95 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ®Yes ❑Yes ❑Yes ❑Yes <br /> condition to respond when the substance ❑ No ® No ❑ No ❑ No <br /> reaches the appropriate level? n section V. (Specify n section V. <br /> (Specify i ) ( p fyi ) (Specify in section V.) (Specify in section V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail El ® Fail ❑ Pass ❑ Fail ❑ Pass El Fail <br /> V. COMMENTS <br /> All items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> System Failure due to drop tube stuck due to rusted riser. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS IN996MINNT <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,title 23,division 3, <br /> chapter 16,section 2637.2 and all the informatio contained herein is accurate. <br /> UST Service Technician Signature <br /> if the facility has more components than thbf formiaccommk4tes,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System ID=Identification,UST=Underground storage tank,ICC=Intenratlonal Code Council,AN=Audible and visual <br />