Laserfiche WebLink
0 <br /> TABLE 1 <br /> GROUNDWATER ELEVATION AND ANALYTICAL SUMMARY <br /> ARCO Service Station No 5469 <br /> 130 South Wilson Way,Stockton,California <br /> Elevation Top of Well Static Water Groundwater Groundwater Ethyl- Total <br /> Well Top of Casing Screen Level Elevation Flow GRO+ Benzene Toluene benzene Xylenes MTBE[IJ <br /> Number Date (fee(ms]) (feet b s) (feet b s) (feet ms I) Direction µ L µ;1L µ L µ L µ L µ L <br /> NOTES <br /> +=Results through the first quarter 2004 include purgeable hydrocarbons in the range of C6-C 10 GRO Gasoline Range Organics QA/QC Review <br /> GRO analyzed using EPA Method 8015E All other analytes analyzed using EPA Method 8260B MTBE=Methyl tert butyl ether A=Data accepted without qualification <br /> (I]MTB£was analyzed using USEPA Method 8020 NA=Not analyzed J-Data accepted widi qualification <br /> [21 MTBE was analyzed using USEPA Method 8260 NC=Not calculated R=Data rejected <br /> [3]The value reported exceeds the calibration curve,but not the linear range NS=Not sampled <br /> [4]Chromatogram Pattern Weathered Gasoline C6-C12 msl=mean sea level <br /> [51 The reporting limits for this sample have been raised due to the high level of a target compound bgs=below ground surface <br /> [6]The reporting limn(s)for this sample have been raised due to high levels of non target mteferents µg/L=micrograms per liter <br /> [7]Sample was diluted due to high levels of Benzene <=Below detection limit for the analytical methods used <br /> [8]Hydrocarbon pattern is present in the requested fuel quantitation range but does not resemble the pattern of the requested fuel <br /> (91 Sample was reanalyzed past EPA recommended holding time <br /> [10]The sample was diluted due to the presence of high levels of target analytes resulting in elevated reporting limits <br /> [1 11 Laboratory report indicates discrete peak at MTBE and Benzene <br /> [12]Laboratory report indicates discrete peak at MTBE <br /> [13]The concentration indicated for this analyte is an estimated value above the calibration range of the instrument <br /> [14]This sample was analyzed beyond the EPA recommended holding time <br /> [15]Based on notes in laboratory report and conversation with laboratory(11119102),this TPHG result is due entirely to presence of MTBL No other compounds eluted in the TPIIG range (Refer to Stratus' <br /> Quarterly Groundwater Monitoring Report Third Quarter 2002 dated November 20,2002) <br /> [16]The continuing calibration standard was outside of the acceptance criteria <br /> f 17]The sample was diluted due to the presence of high le%els of non target analytes resulting in elevated reporting limits <br /> [I 8]Discrete peak @ C6-C7 <br /> [19]Reported result is due to a discrete peak at C5 and has been rejected <br /> [20]Analyte was also reported in the associated laboratory blank as well as in the sample Result should be considered not detected <br /> 121]Initial results maybe biased high as shown by surrogate recoveries above method acceptance limits(due to matrix interference) Sample re-analyzed outside of EPA recommended hold time Initial result reported in the table,and <br /> should be considered an estimate <br /> [22]Initial result was an estimate,beyond the calibration range of the instrument Sample re analyzed beyond the EPA recommended hold time Initial result reported in the table <br /> [23]The reported results may be biased low since the analyses for these analytes were performed beyond the EPA recommended holding time of 14 days <br /> [241 The reported results may be biased low as demonstrated by a low surrogate recovery due to matrix interference <br /> [25]Initial result not confirmed by re-analysis Re analysts performed beyond hold time Initial result reported in the table,should be considered an estimate <br /> [26]The reported result may be biased low as demonstrated by a low surrogate recovery <br /> [27]Discrete peak @ C5 <br /> [28]Analyzed EPA Method 8260B <br /> [29]The reported result may be biased low due to a low average percent recovery reported in the associated MS/MSD analysis <br /> [30]The reported result is partly due to a discrete peak in the quantitation range(probably M CBE) 11 <br /> 5r>zArus <br /> Arco_5469_Quarterly_Data <br /> Il of II <br />