Laserfiche WebLink
i • • <br /> TABLE 1 <br /> GROUNDWATER ELEVATION AND ANALYTICAL SUMMARY <br /> ARCO Service Station No. 5469 <br /> 130 South Wilson Way, Stockton,California <br /> Elevation Top of Well Static Water Groundwater Groundwater Ethyl- Total <br /> Well Top of Casing Screen Level Elevation Flow TPHG Benzene Toluene benzene Xylene MTBE[l] <br /> Number Date feet msi (feet b s) feet b s feet msl Direction µ L L L µ µ L PgtL <br /> MW-10 06/25/01 16.40 59 38.00 -21.60 E-NE NS NS NS NS NS NS <br /> P 06/28/01 16.40 38.18 -21.78 NC <50 51 <0.5 <0.5 <0.5 264[2] <br /> P 09/14/01 16.40 39.64 -23.24 NE 88 4.1 <0.5 <0.5 <0.5 44[2] <br /> P 12/14/01 16.40 40.52 -24.12 NE 77[8] <0.50 <0.50 <0.50 <0.50 35[2] <br /> P 02/21/02 16.40 40.50 -24.10 E-NE <50 1.2 <0.50 <0.50 <0.50 27[2] <br /> P 04/23/02 16.40 40.47 -24.07 NE <50 1.2 <0.50 <0.50 <0.50 35[2] <br /> P 09/19/02 16.40 42.46 -26.06 NE 54[12] 1.0 <0.50 <0.50 <0.50 66[2] <br /> sl mean sea level NS=Not sampled <br /> g=below ground surface NA=Not analyzed <br /> g/L=micrograms per liter c=Below detection limit for the analytical methods used. i <br /> [11 MTBE was analyzed using USEPA Method 8020. NC=Not calculated <br /> [21 MTBE was analyzed using USEPA Method 8260. <br /> [31 The value reported exceeds the calibration curve,but not the linear range. <br /> [4]Chromatogram Pattern: Weathered Gasoline C6-C 12. <br /> [51 The reporting limits for this sample have been raised due to the high level of a target compound. <br /> [6]The reporting limit(s)for this sample have been raised due to high levels of non-target inteferents. <br /> [7]Sample was diluted due to high levels of Benzene. <br /> f 8]Hydrocarbon pattern is present in the requested fuel quantitation range but does not resemble the pattern of the requested fuel. {, <br /> [91 Sample was reanalyzed past EPA recommended holding time. <br /> [10]The sample was diluted due to the presence of high levels of target analytes resulting in elevated reporting limits <br /> 11]Laborawry report indicates discrete peak at MTBE and Benzene <br /> [121,Laboratory report indicates discrete peak at MTBE <br /> [131 The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. <br /> [14]Sample analyzed beyond the EPA recommended holding time. <br /> [15]Based on notes in laboratory report and conversation with laboratory(11/19/02),this TPHG result is due entirely to presence of MTBE. No other compounds eluted in the TPHG range. (Refer to Stratus' <br /> Quarterly Groundwater Monitoring Report,Third Quarter 1002, dated November 20,2002). <br /> 5TKATU5 <br /> Arco_5469_Quarterly_Data <br /> 5 of 5 <br />