Laserfiche WebLink
TABLE 5 <br /> Analytical Parameter Summary <br /> ARCO Service Station No.5469 <br /> i <br /> 130 South Wilson Way,Stockton,California <br /> Distance to Ferrous Total Heterotrophic Nitrate Sulfate Sulfite Phosphate <br /> Well nearest COD' DO Z ORP3 iron 4 iron 5 plate count 6 TOC 7 as NO3 s as SO4 a as SO,' Ortho as P 3 TDS 11 <br /> Number Dateinjection we[ m M9IL m m CFU/ml m L mWL m mWL malL m <br /> t NOTES: <br /> t COD was analyzed using EPA Method 410-4 pglL=micrograms per liter QA/QC Review: <br /> z Dissolved oxygen(DO)was analyzed using EPA Method 360.1 NA—Not analyzed A=Data accepted without qualification <br /> Oxidation reduction potential(ORP)was analyzed using ASTM D1498-76 3=Data accepted with qualification <br /> 1 4 Ferros iron was analyzed using Hach Method 8146 NS—Not sampled R=Data rejected <br /> s 5 Total iron was analyzed using EPA Method 200.7 NP=Not Purged <br /> 6 Heterotrophic plate count was conducted using SM 9215 B <=Below detection limit for the analytical methods used. <br />{ 'Total organic carbon was analyzed using EPA Method 415,1 <br /> $Nitrite,nitrate,sulfates and phosphates were analyzed using EPA Method 300.0 <br />{ 'Sulfite was analyzed using EPA Method 377.1 <br /> r i <br /> 0 Total alkalinity was analyzed using SM 2320B <br /> i <br /> i Total solids were analyzed using EPA Method 160.1 <br /> r [1]The sample was analyzed beyond the EPA recommended holding time. <br /> [2]The incubation was performed at 35 degrees C for 48 hours with plate count agar. <br /> 3)The sample was received beyond the EPA recommended holding time. <br /> 41 This sample was analyzed beyond the EPA recommend hold time(8 hrs). The sample was kept on ice at 5 degrees C and analyzed within 24 hours of sample collection <br /> , <br /> [5]This sample was prepared outside the 8 hour recommended holding time for this analysis- <br /> 61 Sampfe result may be biased high. Matric spike and matrix spike duplicate recoveries exceed upper control limits JJI <br /> - )Sample result may be biased low- Matrix spike duplicate recovery exceeds lower control limit. Matrix spike recovery was within control limits- 1 <br /> 1 Reported results may be biased low since the analyses for these analytes were performed beyond the US EPA recommended holding time. <br /> 91 The method blank contains this analyte at a concentration above the reporting limit,however,the concentration is less than 5%of the sample result,which is negligible according to method criteria. <br /> 10]The reporting limit fur this analyte has been raised to account for matrix interference. <br /> 111 The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. <br /> 121 Confirmatory analysis was past EPA recommended holding lime. <br /> 13]This sample was originally analyzed within the EPA recommended hold time. Re-analysis for confirmation or dilution was performed past the recommended hold time. <br /> 141 Reported results may be biased high since the analyses for these analytes were performed beyond the US EPA recommended holding time. <br /> I <br /> s <br /> sneRrus � <br /> Arco_5469 0&tvl_Data <br /> 4of4 <br />