s <br /> TABLE 5 <br /> Analytical Parameter Summary <br /> ARCO Service Station No.5469 <br /> 130 South Wilson Way,Stockton,California <br /> Distance to Ferrous Total Heterotrophic Nitrate Sulfate Sulfite Phosphate <br /> Well nearest COD' D02 ORP' iron" irons plate count e TOC' as NO3 a as SOq s as S03 9 Ortho as P s MS" QA/QC <br /> Number Date in'ection well m m m m CFU/ml m m m m m mWL Review <br /> NOTES; <br /> 'COD was analyzed using EPA Method 410.4 pgH.=micrograms per liter QA/QC Review: <br /> z Dissolved oxygen(DO)was analyzed using EPA Method 360.1 NA=Not analyzed A=Data accepted without qualification <br /> 'Oxidation reduction potential(ORP)was analyzed using ASTM D1498-76 l=Data accepted with qualification <br /> 14 Ferros iron was analyzed using Hach Method 8146 NS=Not sampled R=Data rejected <br /> 5 Total iron was analyzed using EPA Method 2003 NP=Not Purged <br /> 6 Heterotrophic plate count was conducted using SM 9215 B <=Below detection limit for the analytical methods used. <br /> 7 Total organic carbon was analyzed using EPA Method 415,1 <br /> r Nitrite,nitrate,sulfates and phosphates were analyzed using EPA Method 300.0 <br /> n Sulfite was analyzed using EPA Method 377.1 <br /> 10 Total alkalinity was analyzed using SM 2320B <br /> Total solids were analyzed using EPA Method 160.1 <br /> [11 The sample was analyzed beyond the EPA recommended holding time. <br /> [21 The incubation was performed at 35 degrees C for 48 hours with plate count agar. <br /> [31 The sample was received beyond the EPA recommended holding time. <br /> 14)This sample was analyzed beyond the EPA recommend hold time(8 hrs). The sample was kept on ice at 5 degrees C and analyzed within 24 hours of sample collection. <br /> 15)This sample was prepared outside the 8 hour recommended holding time for this analysis. <br /> 161 Sample result may be biased high. Matric spike and matrix spike duplicate recoveries exceed upper control limits. <br /> [71 Sample result may be biased low. Matrix spike duplicate recovery exceeds lower control limit. Matrix spike recovery was within control limits. <br /> [81 Reported results may be biased low since the analyses for these analytes were performed beyond the US EPA recommended holding time. <br /> [91 The method blank contains this analyte at a concentration above the reporting limit;however,the concentration is less than 5%of the sample result,which is negligible according to method criteria. <br /> I <br /> 57KATU5 <br /> Arco_5469_0&M_Data <br /> 4 of 4 ' <br />