TABLE 5 <br /> Analytical Parameter Summary <br /> ARCO Service Station No 5469 <br /> 130 South Wilson Way,Stockton,California <br /> Distance to Ferrous Total Heterotrophic Nitrate Sulfate SulEte Phosphate <br /> Well nearest COD l DO z Ow iron° irons plate count 6 TOC' as NO3 s as SO4 a as S03 9 (Ortho)as P a l pg t l <br /> Number Date linjectionwelli m m in m CFUImI rnwL m m niEj 1119/1, <br /> m <br /> NOTES <br /> I COD was analyzed using EPA Method 410 4 WL=micrograms per liter QA/QC Review <br /> 2 Dissolved oxygen(DO)was analyzed using EPA Method 360 1 NA=Not analyzed A=Data accepted without qualification <br /> I Oxidation reduction potential(ORP)was analyzed using ASTM D1498 76 J=Data accepted with qualification <br /> °Feros tron was analyzed using Hach Method 8146 N$=Not sampled R=Data[elected <br /> 5 Total von was analyzed using EPA Method 200 7 NP=Not Purged <br /> 6 Heterotrophic plate count was conducted using SM 9215 B <=Below detection linut for the analytical methods used <br /> 7 Total organic carbon was analyzed using EPA Method 415 I <br /> 6 Nitrate nitrate sulfates and phosphates were amalyZed using EPA Method 300 0 <br /> 9 Sulfite was analyzed using EPA Method 377 l <br /> is Total alkalmiry was analyzed using SM 2324E <br /> i i Total solids were analyzed using EPA Method 160 l <br /> [Il The sample was analyzed beyond the EPA recommended holding time <br /> 12]The incubation was performed at 35 degrees C for 48 hours with plate count agar <br /> 13]The sample was received beyond the EPA recommended holding time <br /> [4]This sample was analyzed beyond the EPA recommend hold time(9 his) The sample was kept on ice at 5 degrees C and analyzed within 24 hours o£sample collection <br /> [51 This sample was prepared outside the 8 hour recommended holding time for ties analysts <br /> [6]Sample result maybe biased high Mamc spike and matrix spike duplicate recoveries exceed upper control]antes <br /> [7]Sample result maybe biased low Matrix spite duplicate recovery exceeds lower control limit Matrix spike recovery was within control limits <br /> [81 Reported results may be biased low since the analyses for these analytes were performed beyond the US EPA recommended holding time <br /> [9]The method blank contains this analyte at a concentration above the reporting limit however the concentration is less than 5%of the sample result,which is negligible according to method criteria <br /> 110]The reporting limit for this analyte has been raised to account for matrix interference <br /> I i I]The concentration indicated for this analyte is an estimated value above the calibration range of the instrument <br /> 1121 Confirmatory analysis was past EPA recommended holding time <br /> [131 This sample was originally analyzed within the EPA recommended hold time Re-analysts for confirmation or dilution was performed past the recommended hold time The result from the initial analyses are reported in the Table <br /> [141 Reported results may be biased high since the analyses for these analytes were performed beyond the US EPA recommended holding time <br /> [15)Reported result should be considered estimated since the analyses were performed beyond the US EPA recommended holding time <br /> [ <br /> 16]Repotted result may be biased low as indicated by a low average percent matrix spike recovery reported in the associated MS/MSD analysis. <br /> [171 The reported result may be estimated since the analyses for these analytes were performed beyond the US£PA recommended holding time <br /> [18]The repotted result may be biased since the analyses for these analytes were performed beyond the US EPA recommended holding time <br /> 119]The reported result should be considered estimated due to a high relative percent difference reported between the primary and laboratory duplicate samples <br /> 5TKA7U5 <br /> Ano-5469-0&M_Data <br /> 5 of <br />