Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNT Y-- <br /> c/ `p' Greorne5S grows hey,. Time In: 1048 am <br /> Time Out: 11:47 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: IN SHAPE SPORTS CLUB-TRACY Date: 06/23/2020 <br /> Address: 101 S TRACY BLVD, TRACY 95376 <br /> Owner/Operator: TRACY ATHLETIC CLUB Telephone: (209)836-2504 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #12 pH Level MAJOR <br /> OBSERVATIONS:The pH for the pool was measured at or above 8.0 during my initial inspection of the outdoor pool. <br /> Management later added three gallons of muriatic acid and the pH was then measured at or below 7.0. Pool closure due to <br /> pH not maintained between 7.2-7.8. Pool closure until a correction can be made and a re-inspection has been conducted. <br /> CALCODE DESCRIPTION:Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The handrails to enter the pool from the northern part of the pool is currently loose.Tighten and secure <br /> to ensure a a guest does not fall into the body of water. Correct before operation. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111 B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The influent and effluent pressured currently contain a pressure difference greater than 10 psi. Consider <br /> backwashing to ensure filters are maintained. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31236)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 31256)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 70 gpm Chlorine: 5.4 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: 7.0 or lower Combined chlorine: 0 ppm <br /> NOTES <br /> FA0003097 PR0360531 SCO01 06/23/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />