Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNT Y-- <br /> c/ `p' Greorne5S grows hey,. Time In: 9.40 am <br /> Time Out: 10:30 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: MG WATERSTONE APARTMENTS LP Date: 06/25/2020 <br /> Address: 1951 W MIDDLEFIELD DR, TRACY 95377 <br /> Owner/Operator: MG WATERSTONE APARTMENTS LP Telephone: (209)830-1580 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool lights are currently not functioning but the pool deck contains lights on the outskirts of the pool. <br /> Maintenance stated that the lights turn on every night. Repair lights inside of pool or disconnect and have a certified <br /> electrician state that power is no longer being provided to the light fixtures. Correct immediately. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter is currently stuck or broken. Repair or replace before next routine inspection. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The influent gauge is currently broken due to the needle displaying 0 while the pump was in operation. <br /> Repair or replace before next routine inspection. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 6.2 ppm Temp: ° F <br /> Cyanuric acid: 80 ppm pH: 7.4 Combined chlorine: 0.2 ppm <br /> NOTES <br /> Routine pool inspection. <br /> Influent: Broken, displays 0 <br /> Effluent: 25 <br /> Official inspection report emailed. <br /> FA0017844 PR0526367 SCO01 06/25/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />