Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: CHESAPEAKE BAY APTS, 2941 W LOWELL AVE, TRACY 95377 <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The lights are currently not in operation. If lights will not be used then have a certificated electrician <br /> remove all power form the light fixtures and provide a sign stating no swimming after dark. If not then repair lights and <br /> monitor if GFI is functioning as well.This is a repeat violation. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:The skimmer near the entrance of the pool currently lacks a float assembly. Provide before next routine <br /> inspection. <br /> The skimmers contain a large amount of debris and it makes it difficult to remove the strainer baskets due to the pressure <br /> increase. Keep skimmers clean at all times. This is a repeat violation. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter is currently stuck or broken at this time. Repair or replace before next routine inspection. <br /> This is a repeat violation. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The effluent gauge is currently broken. Replace with an operating gauge to monitor the water pressure <br /> as it leaves the filter. Correct before next routine inspection. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 40 gpm Chlorine: 0 ppm Temp: ° F <br /> Cyanuric acid: 40 ppm pH: 8.0 Combined chlorine: 0 ppm <br /> NOTES <br /> Routine pool inspection. <br /> Influent: 11 <br /> Effluent: Broken <br /> Pool closure due to pH measuring 8.0 or above and chlorine currently measured at 0 PPM. <br /> Official inspection report emailed. <br /> FA0019820 PR0530268 SCO01 06/25/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />