Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNT Y-- <br /> c/ `p' GreornesS grows hey,. Timeln: 1-10pm <br /> Time Out: 2:08 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: CAMINO REAL MOBILE ESTATES Date: 06/29/2020 <br /> Address: 15820 S HARLAN RD, LATHROP 95330 <br /> Owner/Operator: CAMINO REAL MOBILE ESTATES Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:There is currently no safety signs posted at this time.All signs have been put away to avoid exposure to <br /> the elements since the pool is currently not in use. Provide signage before operation. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool light is currently not functioning. Maintenance stated that Leslie's pool services will come and <br /> service the light in the following week. Repair or replace and correct before operation. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter is currently stuck or broken. Repair or replace to ensure proper flow during filtration of <br /> the pool water. Correct before next routine inspection. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31256) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 2.8 ppm Temp: ° F <br /> Cyanuric acid: 100 ppm pH: 7.8 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0000177 PR0360013 SCO01 06/29/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />