Laserfiche WebLink
t Clayton <br /> ENVIRONMENTAL <br /> C0N5LLTANTS <br /> Page 3 of 10 <br /> Results of Analysis <br /> for <br /> Clayton Environmental Consultants , Inc . <br /> Client Reference : 46514 . 00 <br /> Clayton Project No. 93021 . 91 <br /> Sample Identification: BH-1-2 / Date Sampled: 02/16/93 <br /> Lab Number: 9302191-02A Date Received: 02/17/93 <br /> Sample Matrix/Media: SOIL Date Prepared: 02/18/93 <br /> Preparation Method: EPA 5030 Date Analyzed: 02/19/93 <br /> Analytical Method: EPA 8015/8020 <br /> Limit of <br /> Concentration Detectior� <br /> Analyte CAS # (mg/kg) (mg/kg) <br /> BTEX Gasoline <br /> Benzene 71-43-2 ND 0 . 005 <br /> Toluene 108-88-3 ND / 0 . 005 <br /> Ethylbenzene 100-41-4 NDJ 0 . 005 <br /> p,m-Xylenes -- ND 0 . 005 <br /> o-Xylene 95-47-6 ND 0 . 005 <br /> Gasoline -- ND 0 . 3 <br /> QC Limits M <br /> Surrogates Recovery LCL UCL <br /> a, a, a-Trifluorotoluene 98-08-8 86 50 - 150 <br /> ND Not detected at or above limit of detection <br /> -- Information not available or not applicable <br /> Results are reported on a wet weight hasi , as received <br />