Laserfiche WebLink
1.0 INTRODUCTION <br /> 1.1 Site Location and Description <br /> The subject property is located at 2072 W Yosemite Avenue in Manteca, California at the <br /> intersection of Yosemite Avenue and Airport Way (Figure 1, Page 22) The site is on the <br /> southeast corner of the intersection in a commercial and residential area The site currently has <br /> several uses including a filling station and convenience store, automobile repair, U-Haul truck <br /> rental and propane sales The site is currently owned and operated by Mr Frank Guinta <br />[V 1.2 Background <br /> Tank Removals, Soil Borings and Sampling by GeoAudit, Inc, <br /> A Preliminary Investigation and Evaluation Report was prepared by Geological Audit Services <br /> E (GeoAudit), Inc of Stockton, California in February 1995 The work was performed for the <br /> Bank of Stockton The GeoAudit report stated that in September 1994 three 1,000 gallon motor <br /> oil tanks and one waste oil tank had been removed from the site They reported that there had <br /> been no significant contaminants found at the time of the tank removals <br /> In addition, GeoAudit drilled 10 mechanical borings and three hand augered borings on the site <br /> They collected and analyzed 21 soil samples and nine groundwater samples GeoAudit reported <br /> 18,000 ppm TPH-d, 1400 ppm TPH-g, 1 2 ppm ethylbenzene and 8 3 ppm xylenes at a depth of <br /> three feet in boring IW, hand augered boring adjacent to the diesel dispenser, east of the UST <br /> location They also reported 590 ppm TPH-g, 9 1 ppm TPH-d, 2 5 ppm benzene, 4 4 ppm <br /> toluene, 2 4 ppm ethylbenzene and 1 2 ppm xylenes at a level of 15 feet bgs in boring G138, <br /> approximately 50 feet northwest of the dispenser islands, near Yosemite Avenue <br /> Soil Borings and Sampling by Remedy, Inc. <br /> In April 1997, Remedy completed ten (10) soil borings at the site The Remedy borings were <br /> advanced around the fuel tanks and dispenser islands The borings were completed using Geo- <br /> Probe equipment The final depth of borings was approximately 16 feet Boring B-4, west of the <br /> dispenser island closest to the building, was terminated at a depth of 7 feet due to an underground <br /> concrete obstruction, believed to be associated with the previous structures on the site No <br /> samples were collected from this boring <br /> Groundwater was found at a depth of approximately 12 5 feet below ground surface (bgs) <br /> Several soil samples were found to contain petroleum compounds The highest levels were found <br /> in borings B-2 and B-3, east of the dispenser islands The soil sample from boring B-3, at a depth <br /> of 12 feet, was reported to contain 880 ppm (mg/kg) TPH-g, with 9 2 ppm MTBE, 0 89 ppm <br /> benzene, 15 ppm toluene, 10 ppm ethylbenzene and 63 ppm xylenes <br /> The majority of the groundwater samples from both investigations were found to contain <br /> Remedv, Inc Report of Quarterly Sampling of Drinking Water ""ell Auguvt 28, 1998 <br /> Frank's One Stop, 2072 W Yovemite Avenue Manteca, CA 015Q398 RPT <br /> 1 <br />