Laserfiche WebLink
n <br /> . 130,000 ppb TPH-G, 760 ppb TPH-D, 5,300 ppb benzene, 28,000 p p b <br /> toluene, 3,500 ppb ethyl benzene, 21,000 ppb total xylenes and 21 ,000 <br /> ppb MTBE The highest hydrocarbon concentrations were detected in soil <br /> and groundwater samples collected from borings B-2, B-3, B-5 and B-7 <br /> near the USTs and dispenser islands <br /> 2.3 May 1998 Site_Assessment <br /> In May 1998, Remedy, Inc drilled three soil borings (B-11, CPT-11, and <br /> CPT-12) at the site (Figure 2) Boring B-11 was drilled using mud rotary <br /> drilling but was abandoned due to poor sample recovery A soil sample <br /> collected from 14-feet bgs in boring B-11 contained 13 ppm TPH-G, 140 <br /> ppm TPH-D, 0 006 ppm toluene, 0 013 ppm ethyl benzene and 0 084 p p m <br /> total xylenes No hydrocarbons were detected in the soil sample collected <br /> from 33-feet bgs in this boring Borings CPT-11 and CPT-12 were drilled <br /> using cone penetrometer testing (CPT) The soil sample collected from <br /> 13-feet bgs in boring CPT-11 contained 550 ppm TPH-G, 500 ppm TPH-D, <br /> 0 75 ppm toluene, 3 6 ppm ethyl benzene and 42 ppm total xylenes The <br /> soil sample collected from 75-feet bgs in boring CPT-11 contained 15 p p m <br /> TPH-G, 10 ppm TPH-D, 0 036 ppm toluene, 0 11 ppm ethyl benzene, 0 9 6 <br /> . ppm total xylenes and 0 093 ppm MTBE Other compounds detected in <br /> soil samples from borings B-11 and CPT-11 included up to 0 024 ppm <br /> tetrachloroethene (PCE), 1 1 ppm isopropyl benzene, 9 9 ppm n- <br /> propylbenzene, 10 ppm 1,3,5-trimethylbenzene, 2 9 ppm t-butylbenzene, <br /> 32 ppm 1,2,4-trimethylbenzene, 0 87 ppm sec-butylbenzene, 0 11 p p m <br /> naphthalene and 5 7 ppm n-butylbenzene No hydrocarbons were <br /> detected in any of the soil samples collected from boring CPT-12 The CPT <br /> also provided valuable information on lithologic and hydrogeologic <br /> conditions at depth beneath the site Sediments beneath the site are <br /> primarily sand and sandy silt of relatively high permeability The only <br /> significant low permeability materials were clayey silt layers located <br /> between 26 and 32-feet bgs and 50 and 64-feet bgs (in boring CPT--12 <br /> only) Neither of these layers should be considered a competent aquitard <br /> 2-4 June 1999 UST Removal and Contaminated Soil Excavation <br /> In June 1998, Remedy Construction removed two (2) 10,000 gallon diesel <br /> USTs and four (4) 10,000 gallon gasoline USTs Staining and hydrocarbon <br /> odors were present in soil beneath the USTs Up to 1,100 ppm TPH-G, <br /> 19,000 ppm TPH-D, 14 ppm benzene, 19 ppm toluene, 11 ppm ethyl <br /> . benzene, 120 ppm total xylenes and 23 ppm MTBE were detected in soil <br /> samples collected from the UST excavations Up to 24,000 ppb TPH-G, <br /> 97,000 ppb TPH-D, 490 ppb benzene, 2,700 ppb toluene, 780 ppb ethyl <br /> Frank's One Stop Workplan — December 2000 <br /> -2- <br />