Laserfiche WebLink
• <br /> 44 17933 South Airport Way <br /> The domestic well at the above address is constructed with 55-inch ID <br /> steel casing The total depth of the well is 84-feet bgs based on the initial <br /> well inspection The video log of the well confirmed this depth The <br /> video log of the well indicates that the casing ends at approximately 72- <br /> feet <br /> 2- <br /> feet bgs, with the remainder of the well being open hole to a total depth <br /> of 83-feet bgs Casing seams were noted at 7-feet, 27-feet, 47-feet, and <br /> 67-feet bgs No slots or holes were visible in the casing Water apparently <br /> entered the well through the open-hole between 72 and 83-feet bgs The <br /> cement bond log did not show evidence of any cement from the SWL of <br /> 11 5-feet bgs to a depth of 69-feet bgs The pump intake was located 30- <br /> feet bgs Since no cement seal was present in this well, this well would be <br /> considered a potential conduit for the downward movement of MTBE in <br /> the site vicinity <br /> 4.5 17866 South Alrj)ort Way (Irrigation well) <br /> The irrigation well at the above address is constructed with 5 75-inch I D <br /> • steel casing The total depth of the well is 46-feet bgs based on the initial <br /> well inspection performed The video log camera could not be advanced <br /> beyond an obstruction that was encountered at a depth 41-feet bgs The <br /> following was observed during the video logging of the well Holes were <br /> observed at 5-feet, 7-feet, and 9-feet bgs A small hole or perforation, as <br /> well as what appeared to be a crack in the casing, was observed at 26-feet <br /> bgs Seams were present at 8-feet and 28-feet bgs Two holes and vertical <br /> slots were observed at 30-feet Vertical slots appeared to begin at 29-feet <br /> bgs, and were observed at 31-feet, 34-feet, and 36-feet The cement-bond <br /> log for this well did not show signs of cement from the SWI- of 10-feet bgs <br /> to 26-feet bgs However, good cement was noted from 26-feet bgs to 36- <br /> feet <br /> 6- <br /> feet bgs This interpretation, however, would suggest that cement extends <br /> 6 to 7 feet below the top of the vertical slots Water enters this well <br /> through slots in the casing below 29-feet bgs The pump intake was <br /> located at a depth of 25-feet bgs It is ASE's opinion that this well could <br /> potentially be a conduit for the vertical migration of MTBE <br /> 4-6 17866 South Airport Way(Domestic well)_ <br /> The domestic well at the above address is constructed with 6 75-inch I D <br /> steel casing The total depth of the well is 61-feet bgs based on the initial <br /> well inspection performed The video log camera could not be advanced <br /> beyond an obstruction that was encountered at a depth of 44-feet bgs A <br /> Franks One Stop Report -- February 2001 <br /> -4- <br />