Laserfiche WebLink
SAN '�d DAQ II II Environmental Health Department <br /> C0L.IJT`o' <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GTS Transmissions and Sales 1810 W FREMONT ST, STOCKTON July 23, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 6 HSC 25505(a)(2) Failed to complete and/or submit a site map with all required content. <br /> A site map was not submitted as part of the business plan. A site map shall contain a north orientation, loading <br /> areas, internal roads, adjacent streets, storm and sewer drains, access and exit points, emergency shutoffs, <br /> evacuation staging areas, hazardous material handling and storage areas, and emergency response equipment. If <br /> a site map element is not applicable for your facility then list it on the map and label as"NA". Immediately log into <br /> the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, upload the correct or updated <br /> information, and submit to the EHD for approval. <br /> This is a minor violation. <br /> 7 HSC 25505(a)(3) Failed to establish and/or submit emergency response procedures for a release or threatened <br /> release. <br /> The facility does not have emergency response procedures documentation. A business plan shall include the <br /> following emergency response procedures for a release or threatened release of hazardous materials, including, but <br /> not limited to,the following: <br /> -immediate notification of local emergency personnel and the Environmental Health Department(EHD) <br /> -procedures for the mitigation of a release or threatened release to minimize any potential harm or damage to <br /> persons, property, or the environment <br /> -evacuation plans and procedures, including immediate notice,for the site <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, upload the <br /> correct or updated information, and submit to the EHD for approval. <br /> This is a Class II violation. <br /> 8 HSC 25505(a)(4) Failed to submit a training program or program is not reasonable or adequate for facility. <br /> The facility does not have a documented emergency response training program. <br /> Training programs for all employees and annual training, including refresher courses, shall include familiarity with <br /> the facility's Emergency response plans and procedures in the event of a release or threatened release of a <br /> hazardous material.Training shall cover, but not limited to, all of the following: <br /> (A) Immediate notification contacts to the appropriate local emergency response personnel and to the unified <br /> program agency. <br /> (B)Procedures for the mitigation of a release or threatened release to minimize any potential harm or damage to <br /> persons, property, or the environment. <br /> (C) Evacuation plans and procedures, including immediate notice,for the business site. <br /> These training programs may take into consideration each employee's job roles. <br /> Immediately prepare the facility's training program, log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br /> This is a Class II violation. <br /> FA0021424 PR0537308 SCO01 07/23/2020 <br /> EHD 19-01 Rev.9/20/2019 Page 3 of 4 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />