S0 JOA U 1 Environmental Health Department <br /> U ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J&B AUTO BODY 2200 COUNTRY CLUB BLVD, STOCKTON January 03, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br /> OBSERVATION: The following were observed near paint wastes storage area: <br /> -One white pick-up truck observed with absorbent and transmission fluid accumulating underneath. Operator states <br /> that he applied absorbent to leaking transmission fluid. <br /> REGULATION GUIDANCE:A hazardous waste generator must maintain and operate its facility to minimize the <br /> possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous <br /> waste constituents to air, soil, or surface water which could threaten human health or the environment. <br /> CORRECTIVE ACTION: Immediately clean accumulating transmission fluid and absorbent. Manage the waste <br /> according to Title 22 California Code of Regulations for hazardous waste. Submit a statement and supporting <br /> documentation to the San Joaquin County Environmental Health Department describing the storage and final <br /> disposition of the cleaned up waste. <br /> This is a repeat violation, Class II. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The following were observed in paint waste storage area: <br /> -Secondary containment for four 55 gallon paint waste drums observed with accumulating debris and liquid. <br /> -Secondary containment for 30 gallon used oil drum observed with accumulating oil and oily debris. <br /> -One expired fire extinguisher found on the ground. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the secondary containment and fire extinguisher into proper working order by repair, <br /> replacement or testing. Provide a corrective action statement to the San Joaquin County Environmental Health <br /> Department within 30 days. <br /> This is a minor violation. <br /> FA0018383 PR0538583 SCO01 01/03/2020 <br /> EHD 22-01 Rev.9/20/2019 Page 6 of 9 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />