COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLIFTON COURT
>
14333
>
2200 - Hazardous Waste Program
>
PR0538593
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2020 3:47:02 PM
Creation date
7/24/2020 8:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0538593
PE
2220
FACILITY_ID
FA0016950
FACILITY_NAME
FERGUSON RANCH LLC
STREET_NUMBER
14333
Direction
W
STREET_NAME
CLIFTON COURT
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
18925024
CURRENT_STATUS
02
SITE_LOCATION
14333 W CLIFTON COURT RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
View images
View plain text
i <br /> i <br /> i <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205-6232 <br /> Telepho'e: (209) 468-3420 Fax: (209) 468-3433 Web: www. sjgov. org/ehd <br /> Small Quan jity Hazardous Waste Generator lnspectiortRep ort ' <br /> Facility Name: I Facility Address: Date ; <br /> FERGUSON FARMS INC SITE 1 NORTH 14333 W CLIFTON CT RD STOCKTON Aril 26 2017 <br /> Preparedness and Prevention <br /> 301 CCR 66262 . 34(d) (2) Facility not maintained to minimize the release of a hazardous waste ❑ V o R ❑ COS <br /> 302 CCR 66262. 34(d)(2) Failed to maintain required emergency equipment ❑ V o R o COS <br /> 303 CCR 66262. 34(d) (2) Failed to maintain all communication or alarm systems, spill control , or decontamination equipment ❑ V ❑ R o COS <br /> 304 CCR 66262 . 34(d) (2) Failed to maintain adequate aisle space for unobstructed response to emergencies ❑ V ❑ R ❑ COS <br /> Container Management <br /> 401 CCR 66262. 34(d) (2) Failed to store hazardous waste in a container that is in good condition ❑ V ❑ R o COS <br /> 402 CCR 66262. 34(d) (2) Failed to store hazardous waste in a compatible container o V ❑ R ❑ COS <br /> 403 CCR 66262 . 34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste ❑ V ❑ R o COS <br /> 404 CCR 66262 . 34(d) (2) Failed to inspect hazardous waste storage areas at least weekly ❑ V ❑ R ❑ COS <br /> 405 CCR 66262 . 34(d) (2) Failed to manage incompatible wastes in containers properly ❑ V ❑ R ❑ COS <br /> 406 CCR 66261 . 7 Contaminated container not marked with date emptied or managed within one year of being emptied ❑ V o R o COS <br /> 407 CCR 66262. 34(e) (1 )(A) Satellite accumulation container not located near point of generation or under control of operator o V o R o COS <br /> 408 CCR 66262 .34(e)(2) Satellite accumulation exceeded 55 gallons of HW (or one quart of acutely HW) per waste stream To V ❑ R o COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank ❑ V ❑ R o COS <br /> 502 CCR 66262. 34(d)(2) Tank system inspections of discharge systems, monitoring equipment, and tank levels not done daily ❑ V ❑ R ❑ COS <br /> 503 CCR 66262 . 34(d) (2) Tank system inspections of construction materials , fixtures, and surrounding areas not done weekly ❑ V ❑ R ❑ COS <br /> 504 CCR 66262 . 34(d) (2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment o V ❑ R ❑ COS <br /> 505 CCR 66262. 34(f) Failed to completely label stationary hazardous waste tanks ■ V o R o COS <br /> Labeling and Storage <br /> 601 CCR 66262. 34(d) I Stored hazardous waste onsite greater than 180 days ■ V o R o COS <br /> I <br /> ed waste on site longer than one year or 180 days after fill date ❑ V ❑ R ❑ COS <br /> 262. 34 e 1 B Stored satellite accumulated y y <br /> 602 CCR 66 ( )( ) ( ) i 9 <br /> 603 CCR 66262. 34(e)( 1 ) (C) Failed to mark initial accumulation start date on satellite containers ❑ V ❑ R ❑ COS <br /> 604 CCR 66262. 34(e)(3) Failed to mirk satellite containers with date filled within three days o V o R o COS <br /> 605 CCR 66262. 34(f) Failed to completely label containers or portable tanks of hazardous waste o V ❑ R ❑ COS <br /> 606 CCR 66266. 81 (a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V ❑ R o COS <br /> 607 CCR 66266 . 81 (b) Damaged lead acid batteries not properly managed and labeled o V o R ❑ COS <br /> 608 CCR 66266. 130 Failed to properly manage used oil and fuel filters ■ V ❑ R ❑ COS <br /> 609 HSC 25143 .2 , 25143 . 9 Failed to meet requirements for claimed excluded recyclable materials ❑ V ❑ R ❑ COS <br /> Universal Waste <br /> 701 CCR 66273 .32(a) Failed to notify the EPA RA to obtain an EPA ID # prior to accumulating >5000kg of UW ❑ V o R o COS <br /> 702 CCR 66273 . 32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑ V ❑ R o COS <br /> 703 CCR 66273 .33(a) Failed to store UW batteries in a manner that prevents breakage and release to the environment o V ❑ R ❑ COS <br /> 704 CCR 66273.33(b) Failed to properly manage universal waste lamps ❑ V ❑ R ❑ COS <br /> i <br /> , <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).