My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLIFTON COURT
>
14333
>
2200 - Hazardous Waste Program
>
PR0538593
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2020 3:47:02 PM
Creation date
7/24/2020 8:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0538593
PE
2220
FACILITY_ID
FA0016950
FACILITY_NAME
FERGUSON RANCH LLC
STREET_NUMBER
14333
Direction
W
STREET_NAME
CLIFTON COURT
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
18925024
CURRENT_STATUS
02
SITE_LOCATION
14333 W CLIFTON COURT RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205 -6232 <br /> TelephoI e: (209) 468 -3420 Fax : (209) 468-3433 Web: www. sigov. org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: t <br /> f Facility Address: Date: <br /> FERGUSON FARMS INC SITE 1 NORTH 14333 W CLIFTON CT RD , STOCKTON Aril 26 , 2017 <br /> 1 <br /> SUMMARY OF VIOLATIONS <br /> ( CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 104 CCR 66262 . 34 ( d) (2 ) No modified contingency plan . <br /> An emergency coordinator and modified contingency plan information is not posted at the facility . There must be at <br /> least one emergency coordinator on site or on call to coordinate emergency response measures , and the following <br /> information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br /> extinguishers , spill control equipment , and if present, fire alarm ; and the phone number of the fire department, unless <br /> the facility has a direct alarm . Immediately appoint an emergency coordinator and post the required information at the <br /> area where hazardous waste is being generated . A form is provided that can be used for this purpose. <br /> rr <br /> This is a minor violation. <br /> assi <br /> 105 CCR 66262 . 34 (d ) (2 ) No emergency coordinator. <br /> An emergency coordinator and modified contingency plan information is not posted at the facility . There must be` <br /> least one emergency coordinator on site or on call to coordinate emergency response measures , and the following <br /> information must be posted by a phone : the name and phone number of the emergency coordinator ; location of fire <br /> extinguishers , spill control equipment , and if present , fire alarm ; and the phone number of the fire department, unless <br /> the facility has a direct alarm . Immediately appoint an emergency coordinator and post the required information at the <br /> area where hazardous waste is being generated . A form is provided that can be used for this purpose . <br /> This is a minor violation. <br /> 505 CCR 66262 . 34 (f) Failed to completely label stationary hazardous waste tanks . <br /> The facility has a 500 gallon' used oil tank in the "south " area . The tank is labeled " used oil " only . All hazardous <br /> waste tanks shall be marked with the words " Hazardous Waste " and the accumulation start date . Immediately ensure <br /> that all hazardous waste tanks are marked with the required information . <br /> This is a minor violation . �w � �D "(ZXV �` ��' "T> <br /> h ) .1 ,c( XO(I , rw "-h jcnoO <br /> 601 CCR 66262 . 34 ( d ) Stored hazardous waste onsite greater than 180 days . <br /> Facilities who generate less than 1000 kg of hazardous waste per month and do not exceed 6000 kg of waste stored <br /> on site at any time may store waste on site up to 180 days . The " south " used oil tank was missing an accumulation <br /> start date . Since it cannot be determined how long the hazardous waste has been on site , immediately contact a <br /> licensed hazardous waste hauler to dispose of this waste under manifest. Submit a copy of the manifest to the EHD <br /> within 30 days . <br /> This is a Class II violation. I <br /> 608 CCR 66266 . 130 Failed to properly manage used oil and fuel filters . <br /> Oil filters were stored in open and unlabeled containers . Used oil filters shall be drained of free-flowing oil , stored in a <br /> closed , rainproof container, labeled as " drained used oil filters , " and marked with an accumulation start date . <br /> Immediately label and securely close the filter drums and ensure that all used oil filters are managed in this way . <br /> Properly dispose of the filters within one year of generation and keep the recycling records for three years . \ <br /> This is a minor violation. C + 41wsi � �" X46 �� � � �� � "� � � KI; C% <br /> k ° � c� � � . � 4*1 Fytw5 Xf>: Lo PJC <br /> Page 4 of 5 <br /> I _ <br /> Assoc rv�t <br />
The URL can be used to link to this page
Your browser does not support the video tag.