My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
800
>
2800 - Aboveground Petroleum Storage Program
>
PR0528616
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2021 10:31:20 AM
Creation date
7/24/2020 11:42:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0528616
PE
2832
FACILITY_ID
FA0018371
FACILITY_NAME
MCLANE FOODSERVICE DISTRIBUTION
STREET_NUMBER
800
STREET_NAME
PESCADERO
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21307066
CURRENT_STATUS
01
SITE_LOCATION
800 PESCADERO AVE
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for MCLANE FOODSERVICE DISTRIBUTION as of July <br /> 23, 2020. <br /> Open violations from January 09, 2019 inspection <br /> Violation#711 -Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The two 15,000 gallon diesel tanks were not tested on schedule by qualified personnel. The SPCC plan calls for a <br /> certified STI SP-001 integrity inspection"as soon as possible"since the tanks could not be dated. The SPCC plan <br /> or the inspection checklists in th eSPCC plan do not address the inspection of interstitial space of double walled <br /> tanks, as required by SP-001 inspection checklists. Each aboveground container shall be tested and inspected for <br /> integrity on a regular schedule and whenever repairs are made. The qualifications of personnel performing tests <br /> and inspections,frequency and type of testing and inspections that take into account container size, configuration, <br /> and design shall be determined in accordance with industry standards. Examples of these integrity tests include, <br /> but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br /> emissions testing, or other systems of non-destructive testing. Comparison records and other records of <br /> inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit a copy of <br /> the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> ❑ This violation was corrected This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: S I_ ) 5C-001 <br /> 1'-S P ECTI o ti <br /> O1 09 1 CoIM6T11JE Aci-70ti.5 ,IVEEbED. <br /> STILL- 1U0KK4N1;- jhAQ0 JGN co(uM_:ci(UF <br /> A-Ci 10A/S , OUCE F(MD4-U , wlt-L RECEIVE <br /> FIev41L ST-1 -�P-001 PUOILI !4n'D Fop xw <br /> Tb SJc 'E06 UPiDN RECEIPT. <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.