My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006878- CASE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
345
>
2900 - Site Mitigation Program
>
PR0506426
>
ARCHIVED REPORTS_XR0006878- CASE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2020 11:38:59 AM
Creation date
7/27/2020 9:38:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006878- CASE 2
RECORD_ID
PR0506426
PE
2950
FACILITY_ID
FA0007416
FACILITY_NAME
STEPHENS MARINE INC
STREET_NUMBER
345
Direction
N
STREET_NAME
YOSEMITE
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13526011
CURRENT_STATUS
01
SITE_LOCATION
345 N YOSEMITE ST
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 Quarterly Report - First Quarter 2004 <br /> FIVE STAR MARINA <br /> ' 345 Yosemite Street, Stockton, California <br /> ' 1.0. INTRODUCTION <br /> At the request of Mr Terry McDonald of the Five Star Manna,Advanced GeoEnvironmental, Inc <br /> ' (AGE)has prepared the enclosed quarterlyreport for 345 Yosemite Street,Stockton,California The <br /> scope of work included monitoring and sampling six ground water monitoring wells and preparation <br /> of this report The site and its surroundings are illustrated on Figure 1 Structures, soil borings and <br /> ' monitoring well locations are shown on Figure 2 <br /> Site history and findings from previous site investigations are summarized in Appendix A The <br /> iresults of previous ground water monitoring events are included in the tables of this report <br /> ' 20. PROCEDURES <br /> ' The investigation was conducted in accordance with the Central Valley Regional Water Quality <br /> Control Board(CVRWQCB)and the San Joaquin County Environmental Health Department (EHD) <br /> guidelines for the subsurface investigation of underground storage tank (UST) sites and sampling <br /> of ground water monitoring wells <br /> ' 21 WELL MONITORING AND PURGING <br /> On 27 January 2004, a Solinst water level meter was used to measure the depth to ground water in <br /> ' monitoring wells MW-1 through MW-5 and shallow well MW-UST relative to the tops of the well <br /> casings <br /> ' After ground water depth measurements were collected, wells MW-1 through MW-5 were purged <br /> using dedicated, disposable plastic bailers, and well MW-UST was purged with a Waterra check- <br /> bailer Between five and six gallons of water(a minimum of three casing volumes)were evacuated <br /> from wells MW-1 through MW-5 and approximately two gallons of water were evacuated from <br /> MW-UST Ground water temperature,pH and conductivity(field parameters of ground water)were <br /> measured at 0 5-to 1-gallon intervals during purging using an Oakton water analyzer Field data and <br /> logs are included in Appendix B <br /> t <br /> 22 GROUND WATER SAMPLE COLLECTION <br /> ' Water samples were collected from the monitoring wells using the dedicated plastic bailers or the <br /> dedicated Waterra check-bailer,after allowing the wells to achieve a minimum 80%recovery of the <br /> ipre-purge water volume Immediately upon retneval, samples were transferred into chilled 40 ml <br />