Laserfiche WebLink
1721 WEST YOSEMITE AVENUE,MANTECA, CA SECOR Project No. 50178-001-01 <br /> B. Action Level Table for Chemical Monitoring* <br /> tea, MONFIORING <br /> FREQUENCY/ <br /> LOCATION <br /> CHEMICAL MONITORING (source,arca or LEVEL FOR LEVEL FOR WORK <br /> (OR CLASS) EQUIPMENT TASK NO. breathing zone). RESPIRATOR USE STOPPAGE <br /> Volatile Organic Compounds Flame Ionization Detector 2+ Every 15 minutes in 50 ppm above background 500 ppm in breathing zone <br /> • (Halocarbons&Prugeable) (PID) breathing space. If PID sustained in breathing zone and no TCE tube <br /> >5 ppm above for two minutes and no discoloration. <br /> background in breathing TCE tube discoloration. <br /> zone for two minutes, <br /> pull tube. <br /> BTEX(benzene) Drager 0.5/a benzene tube. 2+ IF PID>5 ppm in Any tube discoloration. 2 ppm-breathing zone. <br /> breathing zone. <br /> TCE Drager 2+ Collect Drager Tube Any tube discoloration. >2 ppm in breathing zone; <br /> sample for breathing visible dust <br /> zone if sustained OVM <br /> at or above background <br /> in breathing zone for <br /> two minutes. <br /> Lead Visual 2+ Continuous Visible Dust <br /> *Record peak readings at every work station. <br /> *Calibrate equipment FID every day. <br /> *Leak check colorimetric tube pump daily. <br /> *Complete Attachment 5(Air Monitoring Equipment Calibration/Check Log)and Attachment 6(Air Monitoring Log). <br /> H:\KAISER\MANTECA\H&SPLAN.RPT -3- <br />