COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2020 1:02:08 PM
Creation date
7/27/2020 2:09:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S0 JOA U 1 Environmental Health Department <br /> U ;� i ` I AMENDED <br /> 11/5/2019 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY MARKET INC 15 E GRANT LINE RD, TRACY November 01, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> The following maintenance and monitoring records for the last three years were not found on site: <br /> -2018 Overfill Prevention test result <br /> -2019 Secondary Containment test result <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of <br /> all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain all missing maintenance and monitoring records for the last three <br /> years on site and submit copies to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to check and note all required items on the visual inspection reports. <br /> -The"NA"in sections VII through XI were not explained. <br /> During the visual inspection,the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and shall check all required items on the report. Ensure that designated <br /> operators performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> A current copy of the UST operating permit was not found on site. The most recent permit on site was dated <br /> 12/17/2017. A copy of the UST operating permit and all attachments and conditions shall be retained at the facility. <br /> Immediately obtain a copy of the 2019 permit and retain it on site. <br /> This is a minor violation. <br /> 307 CCR 2631(g), 2632(c)Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 87 tank annular sensor failed to activate an audible and visual alarm when tested and,therefore,the tank is not <br /> monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br /> alarm system. The sensor was replaced and retested during the inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0002915 PR0231404 SCO01 11/01/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.